OFF
OFF
Ice storage at normal temperature (RT 15°C, WT above 13°C)
Compressor
ON
Water valve
ON
Actuator motor
Hot gas valve
Pump motor
Fan motor
Bin control switch
Up
OFF
Down
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Cube control
thermistor temp. (°C)
Freeze completion
rate (%)
7-segment display
0°C
100%
60%
30%
0%
Freeze cycle
Defrost cycle
Bin control cycle
Defrost
cycle
Freeze cycle
*1
7s
10s
*2
22s
20s
30s
*2
20s
10s
80s
Defrost completion temp.
Freeze completion temp.
36