52
VII. REMOVAL AND REPLACEMENT OF COMPONENTS
1. PANELS
[a]
FRONT PANEL
1)
Remove the louver and turn off the power switch.
2)
Remove the screw securing the bottom of the front panel.
3)
Remove the front panel. See Fig. 1 in “III. 1. IN CASE OF DIRTY WATER”.
4) Disconnect the drain hose from the ice station.
5)
Remove the connectors from the front panel.
6)
To refit the front panel, reconnect the connectors and drain hose, hook the top onto
the top panel, and secure the bottom with the screw.
[b] TOP PANEL
1)
Remove the front panel.
2) Unscrew and unhook the rear of the top panel and lift it off.
3) To refit the top panel, check that the insulation panel is securely in place before
hooking the backside square hole of the top panel on the rear of the cabinet.
[c] AIR GUIDE
The air guide fitted with a vibration damper on backside is located at the front of the
condenser to prevent noise from the machine compartment.