REMOTE CONTROL
According to the product standard IEC/
EN 60335-2-53 regulating electrical sauna
heaters, a control unit can be used to
remotely control the heater once the
heater is equipped with a safety switch.
Using with a safety switch:
The heater
can be turned on remotely, if the safety
switch circuit is closed. If the circuit is
open, “SAFE” is displayed and the heater
will not start.
Pause time:
These features are limited
by a pause time that prevents the heater
from turning on if it has been less than
6-hours since the heater was last turned
off. Trying to remotely turn the heater on
during the pause time period (6-hours),
text “rESt” is displayed. The heater can be
remotely started after the pause time has
elapsed and “rc” is displayed.
Memory for power failures:
The control
unit resumes operation, if the remote
switch has remained in ON position.
Preset time:
If the control unit is on preset
delay time, it cannot be controlled with a
remote switch. After the preset delay has
passed and the heater is turned on, it can
be turned off with a remote switch.
Operation:
See page 12.
Wiring Schematic:
ProHeat (pages 14).