INSTRUCTIONS FOR
INSTALLATION
The electrical connections of the control
unit may only be made by a licensed
professional electrician and in accordance
with the current regulations. When
the installation of the control unit is
complete, the person in charge of the
installation must pass on to the user the
Instructions for Installation and Use that
come with the control unit and must give
the user the necessary training for using
the heater and the control unit.
INSTALLING THE CONTROL
PANEL
The control panel is splashproof and has
a low operating voltage. The panel can be
installed in the dressing room, or in the
living quarters. If the panel is installed
in the sauna room, it must be installed
at least 1.5’ away from the heater and at
a maximum height of 3’ from the floor.
Figure 4.
Conductor tubing (1-3/16”) inside the wall
structure allows you to thread the data
cable hidden within the wall - otherwise
the installation will have to be on the wall
surface. We recommend you to install the
control panel embedded in to the wall
and far away from possible splashes.
INSTALLING THE POWER UNIT
Install the power unit to a wall outside
the sauna room, in a dry place with an
ambient temperature more than 32°F
(0°C). See figure 5 for instructions on how
to open the power unit cover and how to
fix the unit to the wall.
Note! Do not embed the control unit into
the wall, since this may cause excessive
heating of the internal components of the
unit and lead to damage. See figure 5.
1. Thread the data cable through the hole in the back cover.
2. Fasten the back cover to a wall with screws.
3. Push the data cable to the connector.
4. Press the front cover into the back cover.