4
Note:
Control panel and power unit must be installed in a
dry place; away from spa, pool or shower; not outdoors. A
receptacle shall not be installed inside the sauna room.
Load center shall be supplied
by electrical contractor during
field wiring, and shall be 2 pole
2 breaker subpanel model.
Load center can be located in
other serviceable places, as
well as location shown on this
diagram.
All the wiring to the sauna
heater and accessories shall be
routed away from any direct
radiation from the sauna heater.
Load
Center
Power
Unit
Figure 1. HeatPad10 / HeatPad15 Digital Sauna Control
Control
Panel
TYPICAL SAUNA HEATER CONTROL INSTALLATION
INSTALLATION OF WALL MODEL
HEATER
1. Remove heater from carton and attach
hater to wall with supplied screws. Use
2”x4” backing behind heater. Observe
proper clearances as per page 5 and 6
and table 1.
2. See applicable wiring diagram on page
14 of the HeatPad Precision Sauna
Environment Controller. Heater must
be permanently installed (no pigtails
or plug allowed) and wiring must be
done by a licensed electrician, who
must follow wiring diagram provided
and adhere to local codes. Use proper
A.W.G. rated wire size and use copper
wire suitable for 194°F (90°C) within
NOTE:
CONTROL
PANEL AND
POWER UNIT
MUST BE
INSTALLED IN
A DRY PLACE
AWAY FROM
SPA, POOL,
SHOWER,
AND NOT
OUTDOORS.
Sensor
4”
7”to
12”
42”
WIRE ROOM LIGHT
#14 AWG 194°F / 90°C
MAX. S
A
UNA HEIGHT 8’ - 0”
NORMAL S
A
UNA HEIGHT 7’ - 0”
MIN S
A
UNA HEIGHT IN US
A 6’ 2”
IN CANAD
A 6’ 5”
INSTALL HEATER
WITH #6-2”
SHEET METAL
SCREWS
FLEX METAL CONDUIT
194°F / 90°C WIRE
HIGH LIMIT
SWITCH
Room
Light
sauna walls. Use grounding terminals
provided in sauna heater, control
system, and contactor to properly
ground the equipment as per NEC and
local codes.
3. Inside the heater box there are
two signs. Please place the metal
“CAUTION” sign on the interior wall
of the sauna room directly above
the heater in a visible place. Place
the metal “WARNING” sign outside,
on the door of the sauna room.
“MAINTENANCE INSTRUCTIONS”
are at the end of this manual.