9
CAUTION! ELECTRICIAN OR
SERVICE PERSON!
1. Before servicing heater, control, or
contactor, turn power off at breaker!
2. Open junction box to make sure wires
are tightly secured with no loose
connections. Heater wire and all
connecting wires should be copper.
3. Check for burned spots or short in
wiring of timer or thermostat.
Warranty on parts is void if installer/
electrician fails to follow necessary wiring
information provided or fails to follow
code for proper wire size, amperage, etc.
HIGH LIMIT CONTROL
Note! Only persons authorized to carry
out electrical installations can reset the
high limit control!
Each heater is equipped with a high limit
control which is a safety device. If an
abnormal heating condition should occur,
the heater will automatically shut off, and
it will not come on again until it cools.
To reset the high limit, locate the reset
button at the bottom front of heater and
push upward until contactor kicks in. Be
sure that a GFI has not been installed.
Receptacles OR PLUGS are not allowed in
a sauna room.