background image

Product Specifications 

Power: 3*2 AA* 1.5V alkaline batteries                                  Maximum current

90mA     

Working temperature:

0~70°C/32~158°F                            Display accuracy:

0.5

 

 

Range of temperature adjustment:

5~70°C/41~158°F        Probe sensor:

NTC(10k)1% 

Range of temperature display:

0~70°C/32~158°F                Thread size

M30*1.5 

Insulating condition: Normal environment                            Size(mm)

66*52*82+20mm 

Running program: Set per 1 week as a cycle                          Maximum route

4.5mm 

Description of function : This    actuator will fine turning for valve status of opened ,according to room 

temperature and setting temperature ,to meet better status of power saving for put off the working life of 

battery   

Displays & Buttons   

                                           

 

NO:

 

Display    icon 

7days week programming and 24-hour heating display icon 

Energy saving mode

comfortable mode

,Valve statue

,

Ventilation mode

 

Holiday mode

,Manual Mode

,Automatic Mode ,Boost Mode,Advanced 

options

,Low battery

,Child lock

 

Clock

,manual program

,setting 7days program

,setting 5+2 program

 

Indoor temperature

,setting temperature

 

NO:

 

key 

represent

 

 

1 Automatic and manual keys, holiday mode. 
2 Long press 3s to access programmable mode 

 

1 Decreasing key 
2 Force close valve : Press it until appear “OFF”on the screen 

 

1 Short press to choose running comfort mode or energy saving mode 
2  Press  3s  ,using 

or

to  set  temperature  for  comfort  mode.Press 

again,using 

or

to set temperature for energy saving mode 

 

1 Increasing Key 
2 Force valve open: press it until appear “OP” on the screen 

 

1 Short press ,using it with other key for confirmation function 
2 It is BOOST function for using alone 
3 Long press 3s    to unlock 

Installation and initial commissioning 

 

3s After power-up, left icon is shown 

time setting 

1 See 

  flashing 

press

to set ,minute

using

or

to adjust number 

2 press

to set hour 

using

or

to adjust number

 

3 press

to set week

using

or

to adjust number

then press

to confirm

and remember   

In normal working condition after actuator was finished for adjustment

If you need to modify 

time.,please press

  about 3s

to access setting interface

  then short press

to switch to 

flashing after chose

press

 OK

to set time

method is the same as above 

ADA

is shown on screen,press

to adjust

If the battery and gear reducer and valve 

installation are no problem,

flashing 

Entry into the normal working interface after completion of the adjustment

flashing

 ,

 

Note

breakdown of adjustment

:(

After solved malfunction 

can restart to adjust    by pressing

 

error 

code 

Fault description 

Er1 

Route too short: in the adjustment process, the pin was stuck.which not reach position   
of 2mm away from terminus   

Er5 

The temperature sensor is open or damaged 

 

Low battery,    icon of battery is flashing 

Function description 

Mode

 

explain

 

Automatic Mode

 

press

Run the automatic mode, display main interface   

Manual Mode

 

press

Run the manual mode

Display the main interface . 

In the unlocked state

press

or

to set temperature

 

Holiday mode

 

press

,see 

  is  flashing

press

to  set  temperature

First  set 

temperature  (

/

)  ,next  press

set  days

,(

From  the  start  of  the 

countdown, the end of the holiday to resume automatic mode operation) 
If you want to exit vacation mode

,press

again

can exit by selecting 

manual or automatic mode 

Run comfort mode

 

Short press

  then run comfortable mode   

Run energy saving 

mode 

Under    comfortable    mode, Short press

then    run energy saving 

mode 

Comfort mode 

temperature and 

energy saving mode 

temperature setting 

press

3s,choose

flashing,  then  set  temperature  by  press 

/

 

(default  is  21

°

C)  ,press

again  ,to  set  temperature  for  energy  saving 

mode  by  pressing 

/

  to  adjust  temperature.  Next  press 

  to 

exit ,or auto exit s after 5st

and return back    display interface

 

BOOST 

Short  press

,  ,then    valve  of  fast  heating    is  fully  open,300s 

countdown,  resume  previous  operation  of  state.after  time  is  over  .Press 
any key to exit this function and return to the previous working state. 
300s can be set in the Advanced Options A7 option 