Product Specifications
Power: 3*2 AA* 1.5V alkaline batteries Maximum current
:
90mA
Working temperature:
:
0~70°C/32~158°F Display accuracy:
:
0.5
℃
Range of temperature adjustment:
:
5~70°C/41~158°F Probe sensor:
:
NTC(10k)1%
Range of temperature display:
:
0~70°C/32~158°F Thread size
:
M30*1.5
Insulating condition: Normal environment Size(mm)
:
66*52*82+20mm
Running program: Set per 1 week as a cycle Maximum route
:
4.5mm
Description of function : This actuator will fine turning for valve status of opened ,according to room
temperature and setting temperature ,to meet better status of power saving for put off the working life of
battery
Displays & Buttons
NO:
Display icon
A
7days week programming and 24-hour heating display icon
B
Energy saving mode
,
comfortable mode
,Valve statue
,
Ventilation mode
C
Holiday mode
,Manual Mode
,Automatic Mode ,Boost Mode,Advanced
options
,Low battery
,Child lock
D
Clock
,manual program
,setting 7days program
,setting 5+2 program
E
Indoor temperature
,setting temperature
NO:
key
represent
F
1 Automatic and manual keys, holiday mode.
2 Long press 3s to access programmable mode
G
1 Decreasing key
2 Force close valve : Press it until appear “OFF”on the screen
H
1 Short press to choose running comfort mode or energy saving mode
2 Press 3s ,using
or
to set temperature for comfort mode.Press
again,using
or
to set temperature for energy saving mode
I
1 Increasing Key
2 Force valve open: press it until appear “OP” on the screen
J
1 Short press ,using it with other key for confirmation function
2 It is BOOST function for using alone
3 Long press 3s to unlock
Installation and initial commissioning
3s After power-up, left icon is shown
time setting
1 See
flashing
,
press
to set ,minute
,
using
or
to adjust number
2 press
to set hour
,
using
or
to adjust number
,
3 press
to set week
,
using
or
to adjust number
,
then press
to confirm
,
and remember
In normal working condition after actuator was finished for adjustment
,
If you need to modify
time.,please press
about 3s
,
to access setting interface
,
then short press
to switch to
,
flashing after chose
,
press
”
OK
”
,
to set time
,
method is the same as above
4
“
ADA
”
is shown on screen,press
to adjust
,
If the battery and gear reducer and valve
installation are no problem,
flashing
Entry into the normal working interface after completion of the adjustment
。
flashing
,
Note
:
breakdown of adjustment
:(
After solved malfunction
,
can restart to adjust by pressing
)
error
code
Fault description
Er1
Route too short: in the adjustment process, the pin was stuck.which not reach position
of 2mm away from terminus
Er5
The temperature sensor is open or damaged
Low battery, icon of battery is flashing
Function description
Mode
explain
Automatic Mode
press
,
Run the automatic mode, display main interface
Manual Mode
press
,
Run the manual mode
,
Display the main interface .
In the unlocked state
,
press
or
to set temperature
。
Holiday mode
press
,see
is flashing
,
press
to set temperature
,
First set
temperature (
/
) ,next press
set days
,(
From the start of the
countdown, the end of the holiday to resume automatic mode operation)
If you want to exit vacation mode
,
,press
again
,
can exit by selecting
manual or automatic mode
Run comfort mode
Short press
,
then run comfortable mode
Run energy saving
mode
Under comfortable mode, Short press
,
then run energy saving
mode
Comfort mode
temperature and
energy saving mode
temperature setting
press
3s,choose
,
flashing, then set temperature by press
/
(default is 21
°
C) ,press
again ,to set temperature for energy saving
mode by pressing
/
to adjust temperature. Next press
to
exit ,or auto exit s after 5st
,
and return back display interface
。
BOOST
Short press
, ,then valve of fast heating is fully open,300s
countdown, resume previous operation of state.after time is over .Press
any key to exit this function and return to the previous working state.
300s can be set in the Advanced Options A7 option