background image

WIFI BOILER THERMOSTAT 

HTW-31-WKT19-WF 

 

 

 

RRG. Setting 

 

Long press 

button to enter PRG setting. The weekday is fixed from Monday to Sunday(1~7), each day have 4 

periods(1~4). Each press of 

button can into next item setting. 

The time and temperature of each period i can be set in following steps. 

1). Press 

and hold for 3 seconds, the time display flash, change the value by + and - button. 

2) Press 

button , the temperature display flash(B), change the temperature by + and - button. 

3). Press 

button to next period. 

4). the other period settings follow the same way. 

 

Default Setting: 

 

Period 

 

Time 

Temp 

Time 

Temp 

Time 

Temp 

Time 

Temp 

12345(Mon.~Fri.) 

7:00 

22

 

8:30 

19

 

17:00 

22

 

22:00 

19

 

6(Sat.) 

8:00 

22

 

8:30 

22

 

17:00 

22

 

22:00 

19

 

7(Sun.) 

8:00 

22

 

8:30 

22

 

17:00 

22

 

22:00 

19

 

 

Hour/Date Setting 

Long Press 

button for 2-3 seconds 

You will see 00:00 hour information. Set the minute with up and down buttons. 

Proceed with 

button. 

Set the hour with up and down buttons. 

Proceed with 

button. 

Select the day with up and down buttons. 

Proceed with 

button. 

Save your settings by pressing ON/OFF button or wait about 15 seconds. 

 

Open Window Detection Function 

When the Open Window mode is enabled in the parameter setting, the system will automatically stop heating when it 

detects a sudden drop of room temperature (2°C in 15 minutes as default). This is normally caused when a window or 

door is opened without turning off the heating device. 

The device will return to the previous mode of operation after 30mins, then icon‟”OP “disappear. Press any button will exit 

OWD function during the heating off period 

 

  

Code Pairing  

 

On/off button 

Code pairing button 

Heating on indicator (LED 1) 

Power indicator (LED 2) 