background image

 

        Smart Wifi Multi Stage Thermostat 

                                                                                           

Reference  No.:

 

HTW-81-FN7WF  Series 

 

5/7 

 

Auto: 

In this state, a constant temperature will be kept. Device will activate/ stop heating/cooling system automatically according to 

the setting and room temperature. 

 

Conventional system 

Heat 

Room temp.≤Setting temp.-1

    “Heat on” displays and 1st stage heating system is on;   

Room temp.≤Setting temp.-2

    “Heat on”& “AUX” display and 2

nd

 stage heating system is on;   

(not available for 1 stage heat 

system)

 

Room temp.≥Setting temp., heating system stops and “Heat on” disappears from screen.   

Note: 2

nd

 heat stops and “AUX” disappears when temp. difference is less than 1 

.

 

Cool

   

Room temp.≥ Setting temp.+1 

    “Cool on” displays and 1

st

 stage cooling system is on;   

Room temp.≥ Setting temp.+2 

    “Cool on” stays and 2

nd

 stage cooling system is on ;                 

                                                                               

(not available for 1 stage cool system)

 

        Room temp.≤ Setting temp., cooling system stops and “Cool on” disappears from screen. 

Note:

 

2

nd

 cool stops when temp. difference is less than 1 

.     

 

Heat pump system

 

Heat   

(Changeover valve keep closed)

 

Room temp.≤Setting temp.-1

    “Heat on” displays and 1

st

 stage heating system is on;   

Room temp.≤Setting temp.-2

    “Heat on” stays and 2

nd

 stage heating system is on; 

Room temp.≤Setting temp.-3

    “Heat on”& “AUX” display and Aux heating system is on; 

Room temp.≥Setting temp., heating system stops and “Heat on” disappears from screen.   

Note: Aux heat stops and “AUX” disappears when temp. difference is less than 2 

  2

nd

 heat stops when temp. difference is less 

than 1

 

Cool

      (Changeover valve keep open) 

Room temp.≥ Setting temp.+1 

,

    “Cool on” displays and 1

st

 stage cooling system is on;   

Room temp.≥ Setting temp.+2 

  “Cool on” stays and 2

nd

 stage cooling system is on;         

        Room temp.≤ Setting temp., cooling system stops and “Cool on” disappears from screen. 

Note:

 

2

nd

 cool stops when temp. difference is less than 1

 

Compressor protection 

After an operation of heating/cooling system, there is a 1 min compressor off time to protect compressor. “Wait” will display on 

the screen if next operation is activated within the 1 min period. 

Fan mode setting 

Press 

  to switch among “Fan on & Fan Auto”.

 

 

Fan on

  Fan is always on.

 

 

 

Fan Auto

Fan runs automatically only when heating/cooling system is on. 

(If system is in 

OFF

 state, the fan will always off) 

Mode setting 

Press 

to switch among “

Schedule

Hold

 & 

Hold Until

 (Holiday)” modes.   

Programmable Schedule(Programming) 

        Any icon from 

  stands for one time period, and there are 4 periods can be set in one day. Under the time setting 

mode,  press 

  to  enter  into  time  setting  interface,  the  time  parameter  of  cooling  or  heating  mode  can  be  set.  Press 

  then 

switch among 

7 days 

→ 

5+2 days

 → 

a whole week: [ 

MON→TUE→WED→THU→FRI→SAT→SUN→

MON TUE WED THU 

FRI

SAT SUN

MON TUE WED THU FRI SAT SUN

  ].   

When setting the parameters, press F to exit to the modify interface, then get back to the temperature setting interface.     

1.Press 

 

then  press 

 

or 

  to  change  the  flashing 

hour

minute

  & 

temperature

  value  of  the  chosen  day and  time  period 

(changes in 15 minutes at a time);   

     

Summary of Contents for HTW-81-FN7WF Series

Page 1: ...rmostat App READ CAREFULLY These instructions will help prevent difficulties that might arise during thermostat installation and operation Studying the instructions first may save considerable time an...

Page 2: ...n echo for good human machine communication WIRING INSTRUCTION Cut off power supply at circuit breaker or fuse before installation to avoid fire shock or death WIRING DIAGRAM Step 1 Separate the insta...

Page 3: ...ut 2 2nd stage compressor output heat pump W2 AUX Heat output 2 Auxiliary heat output heat pump No Type Terminals Wiring Compressor delay 0 0 1H 1C conventional R G W Y Diagram conventional systems no...

Page 4: ...ute minute value flashes press or to modify the values Continually press it will switch among Year Month Day Hour Minute Press F to save the status then back to the temperature setting interface displ...

Page 5: ...temp difference is less than 2 2nd heat stops when temp difference is less than 1 Cool Changeover valve keep open Room temp Setting temp 1 Cool on displays and 1st stage cooling system is on Room tem...

Page 6: ...s mode comes after Hold by pressing F again In this mode device will follow the setting temperature and lasting days when users are out for a holiday And then back to follow Schedules after the holida...

Page 7: ...terated or removed that has not been handled or packaged correctly that has been sold as second hand or that has been resold contrary to Country and other applicable export regulations HIDDEN MENU In...

Reviews: