background image

 

                             

Programmable Multi-Stage Smart Thermostat

   

                                   

Reference  No.:

 

HTW-MT08  Series 

 

                                                         

 

- 5 -

                                                                            Version 2020-1.0                                                                                             

******************************Check Thermostat Operation****************************** 

ON/OFF operation 

Press Power button 

  to turn the thermostat on/off. 

Working Mode Operation 

Press 

  to  set  the  thermostat  working  mode  in 

Permanent  Hold,  Using  Schedule

  or

  Temporary  Hold

.  These  functions 

will appear on the screen. 

Permanent Hold

 =Manual Mode. In this mode, press 

 

 

to set temperature manually. 

Temporary Hold

. when you change the temperature setting to a different temperature and it stays at that setting until the next 

schedule change 

Using Schedule

. 7 day separate four periods daily programmable 

Holiday Mode

. Changes temperature setting for a designated number of days. 

 

Real Time Setting 

Press and hold 

  for 5 sec. till the min of time flashes; press 

 

 

to set to set your minute. 

Then press 

  switch to the “hour” and “week day” setting respectively, press 

 

 

to set the values.

 

Programmable Schedule Setting   

After the above time setting, touch the icon 

  each week day”1 2 3 4 5 6 7” will show along the top of the screen. 

press 

 

 

to set the time for the 1st period(Awake). Press the icon   

  then use the 

 

 

arrows to set the temp. for 

the 1st period. Repeat this process for periods 2-4. Default values set as below: 

Schedule Period 

Time 

Set-Points 

Heat 

Cool 

Wake 

6:00 Am 

72

(22

°C

72

(22

°C

Leave 

8:00 Am 

72

(22

°C

72

(22

°C

Return 

11:30 Am 

72

(22

°C

72

(22

°C

Sleep 

01:30 Am 

72

(22

°C

72

(22

°C

System Mode Operation   

Press 

  to select the mode AUTO,COOL,HEAT,OFF,EMER. 

HEAT — Thermostat controls the heating system. 

OFF — Both heating and cooling systems are off. 

COOL — Thermostat controls the cooling system. 

AUTO — Thermostat automatically changes between heating and cooling operation, depending on indoor temperature. 

EMER — Emergency heat cycles to maintain temperature. 

 

 

 

 

Summary of Contents for HTW-MT08 Series

Page 1: ...m USA Italy Wire Diameter for Terminals 2 1 5mm or 1 2 5mm Identify System Type Features Specification SAVE ABOUT 25 ON HVAC ENERGY Save money without compromising your comfort with features like flex...

Page 2: ...Programmable Multi Stage Smart Thermostat Reference No HTW MT08 Series 2 Version 2020 1 0 Display Dimensions...

Page 3: ...g your screwdriver carefully unscrew one wire at a time from the terminal block and attach the corresponding wire label sticker Please note that not all terminals may be used and that there s no stand...

Page 4: ...our wires disconnected and properly labeled you may now safely remove the thermostat base from your wall Mounting and Wiring Your New Thermostat 1 Remove the mounting plate by screw driver and Open th...

Page 5: ...ess to set to set your minute Then press switch to the hour and week day setting respectively press to set the values Programmable Schedule Setting After the above time setting touch the icon each wee...

Page 6: ...ional System 0 Heat Pump System 1 Conventional System 0 Always turn off power at the main power source by removing the fuse or switching the circuit breaker to the off position before installing remov...

Page 7: ...t your region and type in your phone No or email fig 2 3 then you may get a verification code Type in your password and con rm fig 2 4 to complete your registration If you already have an account plea...

Page 8: ...thermostat can not be connected as above steps please try this AP mode connection process On the thermostat During power off status press and hold the arrow icon for 8 sec until the connecting icon a...

Page 9: ...vice name location create group and etc When thermostat runs in programmable mode click the setting symbol at the bottom of the page to switch to the schedule page where you can simply configure the w...

Page 10: ...time Method 1 Click Share with Familay as fig 4 4 Method 2 Click Profile Sent Add Switch on the device Share with New Member Type in the telephone number you would like to share with Method 3 Home pag...

Page 11: ...isplay Check if the terminals between LCD panel and Relay Power Module is loosen 2 Without output but display works Use a new LCD panel or new Relay Power Module for Replacement 3 Room Temp on display...

Reviews: