background image

 

                     

Programmable Single Stage Thermostat 

                                       

Reference  No.:

 

HTW-ST01-B 

 

                                                         

 

- 4 -

                                                                            Version 2019-1.0                                                                                             

******************************Check Thermostat Operation****************************** 

Fan operation 

If your system does not have a G terminal connection, skip to 5.2 Heating system. 

Move FAN switch to ON position. The blower should begin to operate. 

Move FAN switch to AUTO position. The blower should stop immediately. 

Heating system 

Move SYSTEM switch to HEAT position. If the heating system has a standing pilot, be sure to light it. 

Press 

 to adjust thermostat setting room temperature. The heating system should begin to operate. 

Press 

to adjust temperature setting below room temperature. The heating system should stop operating. 

Cooling system 

 

Move SYSTEM switch to COOL position. 

Press 

  to  adjust  thermostat  setting  below  room  temperature.  The  blower  should  come  on  immediately  on  high  speed, 

followed by bold air circulation. 

Press 

   

to adjust temperature setting above room temperature. The cooling system should stop operating. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Typical Wiring Diagram 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for HTW-ST01-B

Page 1: ...power loss No batteries are required Apply to 24VAC or 2 AA alkaline batteries power supply Air Filter change Indicator Low Battery Indicator Temperature calibration 4 or 5 wire compatible C is optio...

Page 2: ...r screwdriver carefully unscrew one wire at a time from the terminal block and attach the corresponding wire label sticker Please note that not all terminals may be used and that there s no standard c...

Page 3: ...ase from your wall Mounting and Wiring Your New Thermostat 1 Install new thermostat base 2 Connect wires to corresponding terminal blocks Match each labeled wire to it s corresponding terminal on the...

Page 4: ...ition If the heating system has a standing pilot be sure to light it Press to adjust thermostat setting room temperature The heating system should begin to operate Press to adjust temperature setting...

Page 5: ...st the temperature The thermostat will control the room temperature at the selected setting until you press the RUN button to restart the program operation Temperature Override When in the program RUN...

Page 6: ...stem at a 0 5 F 0 5 C differential and SL cycles the system at 1 5 F 1 5 C 2 When operated from batteries only the LCD display backlight will be illuminated less than 5 seconds after each button press...

Page 7: ...to be cooler warmer when the building is vacant or during periods of low activity During early morning hours the need for cooling is usually minimal The time of day clock must be set correctly in orde...

Page 8: ...d start time and temperature for RETURN 3 Period and SLEEP 4 Period Press PRGM again and SAT SUN indicating weekend programming parameters setting Repeat step 5 to complete Saturday and Sunday program...