FAULT CODES
In the event of a fault being detected by the
electronics, a code will appear in the LCD
display.
These codes are listed in the following table.
Please Note:
•
Components with a low resistance to
Earth may cause erroneous faults or
loss of the display.
•
Always check relevant wiring and
connector blocks security
before
considering replacing the modules.
•
On ALL automatic programmes; there is no heat during the first 3 minutes.
The first 10 minutes of all automatic cycles is used to calculate the drying time.
•
ONE-SHOT STAT OPERATION
The one-shot thermostat is wired into the Neutral supply of the module.
If the One-Shot Thermostat operates and opens the machine will be 'dead' and the display will
be blank.
A fault code will NOT be displayed.
FAULT Cause
Control
Action
F01
The motor is running when
it should be off.
•
Check if module connector J3 has shorted due to moisture.
•
Replace module.
F02
Open circuit between
module & motor Common.
•
Check security of module connector J3;
•
Test motor Common (TOC);
•
Check wiring between J3 and motor.
F03
Front thermistor open or
short circuit.
•
Check security of module connector J12;
•
Test from connector pins (approximately 500 Kohms);
•
If open or short circuit, test thermistor and wiring between
thermistor and J12 to locate fault.
F04
Pump working when should
be off.
• Check security of module connector J5;
• Check connector for signs of shorting due to moisture;
• Replace module (F04 would normally be caused by a
faulty module).
F05
Pump is not working when
it should be on.
• Check security of module connector J5;
• Check connector for signs of shorting due to moisture;
• Replace module (F05 would normally be caused by a
faulty module).
F06
Not used.
----