Auto Test
Required
•
Hardware Key with a Test Switch (see photo.)
•
Test Lead approximately 1.5 metres long with a 270 K
Ω
resistor in series
with a conductive magnet at one end, and a ring connector at the other.
•
Amp meter
With the machine disconnected from the Electricity supply.
1. Attach the magnet end of the test lead on to the conductivity sensor.
2. Attach the other end of the test lead to an earth point. One of the rear
panel fixing screws is recommended.
3. Connect the Hardware key to the module. (access behind the plinth)
3a Select Cotton High Heat programme on selector.
4. START TEST
4a
Plug the machine into the electricity supply, but do not switch on.
4b
Switch the Test button on the Hardware key, To Test Position
The Display Shows Start Led green, Extra Dry bar, and 2:50
Drum Rotates anti clockwise. No Heat (approx. 1 amp)
4c Press the Post Crease care Button
The Display shows Start Led, Extra Dry bar, 2:50 and Post Care Led.
The Drum Stops
The Drum restarts rotating clockwise. Half heat. (approx. 5 or 6 amps)
4d
Press the Alarm Button
The Display shows Start Led, Extra Dry bar, 2:50 Post Care and Alarm Led’s.
Drum continues to revolve clockwise. Full Heat. (approx 10 to 11amps)
5.
Conductivity Sensor Test
Press the Post Crease Care button again
The Heater Switches Off
The Drum Stops.
The Display shows Extra Dry bar, 2:50 and Alarm Led.
> If the Conductivity Sensor is working correctly.
The Drum Starts to rotate anti clockwise.
The Display shows Start Led green, Extra Dry Bar, 2:50. in the display.
> If the Conductivity Sensor is Faulty
.
The Display briefly flashes END and Start Led flashes green, plus Drying, Cool Tumble and Empty
Water/Clean filter Led’s come on.
The drum does not rotate.
Note:
If a fault is detected the fault code will display in the display on the console and in the Test Plug
screen.
Hardware Key