23
GB
Table of burner and nozzle specifications
CX65SP1 I /HA S
S
R
TC A
Table 1
Liquid gas
Natural gas
Burner Diameter
(mm)
Thermal power
kW (p.c.s.*)
Bypass
1/100
(mm)
Nozzle
1/100
(mm)
Capacity*
g/h
Nozzle
1/100
(mm)
Capacity*
l/h
Nominal Reduced
***
**
Triple.ring (TC)
130
3.25
1.50
2x65
91
236
232
2x99
309
Rapid (Large)
(R)
100 3.00 0.70
41
86
218
214
116 286
Semi-rapid
(Medium) (S)
75 1.90
0.40
30
70
138
136
106 181
Auxiliary
(Small) (A)
55 1.00
0.40
30
50
73
71 79 95
Supply
pressure
Nominal (mbar)
Minimal (mbar)
Maximised (mbar)
28-30
20
35
37
25
45
20
17
25
*
At 15°C and 1013 mbar - dry gas
**
Propane P.C.S. = 50.37 MJ/kg
***
Butane P.C.S. = 49.47 MJ/kg
Natural P.C.S. = 37.78 MJ/m³
TECHNICAL DATA
Oven dimensions
(HxWxD)
32x43.5x40 cm
Volume
57 l
Useful
measurements
relating to the oven
compartment
width 42 cm
depth 44 cm
height 8.5 cm
Burners
may be adapted for use with any
type of gas shown on the data plate
Voltage and
frequency
see data plate
ENERGY LABEL
Directive 2002/40/EC on the label
of electric ovens.
Regulation EN 50304
Energy consumption for Natural
convection – heating mode:
X
Traditional mode
;
Declared energy consumption for
Forced convection Class –
heating mode:
u
Baking.
EC Directives: 2006/95/EC dated
12/12/06 (Low Voltage) and
subsequent amendments -
2004/108/EC dated 15/12/04
(Electromagnetic Compatibility)
and subsequent amendments -
2004/142/EC dated 30/11/09
(Gas) 1275/2008 (Stand-by/ Off
mode)
Data plate, is located inside the flap or, after the oven
compartment has been opened, on the left-hand wall
inside the oven.
!
When inserting the shelf make sure the backstop is at
the rear of the cavity (see image).
Summary of Contents for CX65SP1 I /HA S
Page 59: ...59 GR ...