4
Improper use of the grids can result in damage
to the hob: do not position the grids upside down
or slide them across the hob.
Do not let the burner flame extend beyond the
edge of the pan
Do not use : Cast iron griddles, ollar stones,
terracotta pots and pans. Heat diffusers such as
metal mesh, or any other types. Two burners
simultaneously for one receptacle (e.g.
Fish
kettle).
Should particular local conditions of the delivered
gas make the ignition of burner difficult, it is
advisable to repeat the operation with the knob
turned to small flame setting.
In case of installation of a hood above the cooktop,
please refer to the hood instructions for the correct
distance.
The protective rubber feet on the grids represent
a choking hazard for young children.
After
removing the grids, please ensure that all the feet
are correctly fitted.
INSTALLATION
cuts.
The electrical and gas connections must
comply with local regulation.
Installation,
electrical connections and repairs must be carried
out by a qualified technician. Do not repair or
replace any part of the appliance unless specifically
stated in the user manual. Keep children away from
the installation site. After unpacking the appliance,
make sure that it has not been damaged during
transport. In the event of problems, contact the
dealer or your nearest Aftersales Service. Once
installed, packaging waste (plastic, styrofoam
parts etc.)
must be stored out of reach of
children - risk of suffocation. The appliance must
be disconnected from the power supply before
any installation operation - risk of electric shock.
During installation, make sure the appliance does
not damage the power cable - risk of fire or electric
shock. Only activate the appliance when the
installation has been completed.
This means LPG cylinders, whether partially or
completely full, must not be installed or stored
in rooms or storage areas that are below ground
level (cellars, etc.). It is advisable to keep only the
cylinder being used in the room, positioned so
that it is not subject to heat produced by external
sources (ovens, fireplaces, stoves, etc. ) which
could raise the temperature of the cylinder above
50
°
C.
Should you find it difficult to turn the knobs for the burner, please
contact the After-sales Service, who can replace of the burner tap if
found to be faulty.
The openings use for the ventilation and dispersion of heat must never
be covered.
(in certain models only)
We recommend the appliance should be handled
and installed by two or more persons - risk of injury.
Use protective gloves to unpack and install - risk of
GAS CONNECTION
WARNING : Prior to installation, ensure that the
local distribution conditions (type of gas and gas
pressure) and the configuration of the appliance
are compatible.
Check that the pressure of the gas supply is
consistent with the values indicated in Table 1
(“Burner and nozzle specifications”).
WARNING : The configuration conditions of
this appliance are stated on the label (or data
plate).
WARNING : This appliance is not connected
to a combustion products evacuation device. It
must be installed and connected in accordance
with current installation regulations. Particular
attention must be paid to the relevant
requirements regarding ventilation.
If the appliance is connected to liquid gas,
the regulation screw must be
IMPORTANT : When the gas cylinder or gas
container is installed, it must be properly settled
(vertical orientation).
WARNING : This operation must be perfomed
by a qualified technician
adjusted to the
minimum setting.
The appliance should be connected to the main
gas supply or to a gas cylinder in compliance with
the current national regulations. Before making
the connection, make sure that the appliance is
compatible with the gas supply you wish to use.
If it is not, follow the instructions indicated in the
paragraph "Adapting to different types of gas".
not protrude beyond the edge of the hob.
specific table). Make sure pots on the grates do
WARNING : Modification of the appliance and
its method of installation are essential in order to
use the appliance safely and correctly in all the
additional countries
Use pressure regulators suitable for the gas
pressure indicated in the instruction.
The room must be equipped with an air
extraction system that expels any combustion
fumes.
Liquid petroleum gas sinks to the floor as it
is heavier than air. Therefore, rooms containing
LPG cylinders must also be equipped with vents
to allow gas to escape in the event of a leak.
After connection to the gas supply, check for
leaks
minimum position 2* to check flame stability.
Connection to the gas network or the gas
cylinder may be carryout using a flexible rubber
or steel hose, in accordance with current national
legislation.
in accordance with IGEM/UP/1B. Light up the
burners and turn the knobs from max position 1* to