Installation
!
Please keep this instruction booklet in a safe place for future reference. If
the appliance is sold, given away or moved, please make sure the booklet is
also passed on to the new owners so that they may benefit from the advice
contained within it.
!
Please read this instruction manual carefully: it contains important information
concerning the safe operation, installation and maintenance of the appliance.
Positioning
!
Do not let children play with the packaging material; it should be disposed
of in accordance with local separated waste collection standards (see
Precautions and tips).
!
The appliance must be installed by a qualified professional in accordance
with the instructions provided. Incorrect installation may damage property or
cause harm to people or animals.
Built-in appliances
Use an appropriate cabinet to ensure that the appliance operates properly:
• The panels adjacent to the oven must be made of heat-resistant material.
• Cabinets with a veneer exterior must be assembled with glues which can
withstand temperatures of up to 100°C.
• To install the oven
under the counter
(see diagram) or in a
kitchen unit
,
the cabinet must have the following dimensions:
595 mm.
595 mm.
25 mm.
545 mm.
5 mm.
567 mm.
23 mm.
575-585 mm.
45 mm.
560 mm.
547 mm. min.
!
The appliance must not come into contact with electrical parts once it has
been installed.
The indications for consumption given on the data plate have been calculated
for this type of installation.
Ventilation
To ensure adequate ventilation, the back panel of the cabinet must be
removed. It is advisable to install the oven so that it rests on two strips of
wood, or on a completely flat surface with an opening of at least 45 x 560
mm (see diagrams).
560 mm
.
45 mm.
Centring and fixing
1. Position brackets “
A
” against oven support “
B
”.
2. Position tabs “
C
” against brackets “
A
”. If the thickness of the cabinet side
panel:
• is 16 mm thick: place the tab so that the number 16 written on it is
facing you;
• is 18 mm thick: place the tab so that the part without any text is facing
you;
• is 20 mm thick: do not fit the tab.
3. Fix the brackets and tabs onto the edge of the cabinet side panel using
screws “
D
”.
4. Fix the oven to the cabinet using the screws and plastic washers “
E
”.
D
A
B
D
D
16
16
C
C
E
E
Electrical connection
Ovens equipped with a three-pole power supply cable are designed to operate
with alternating current at the voltage and frequency indicated on the data
plate located on the appliance (see below).
Fitting the power supply cable
1. Open the terminal board by inserting a
screwdriver into the side tabs of the cover.
Use the screwdriver as a lever by pushing
it down to open the cover (see diagram).
2. Install the power supply cable
by loosening the cable clamp screw
and the three wire contact screws
L-N-
.
Connect the wires to the corresponding
terminals: the Blue wire to the terminal
marked (N), the Brown wire to the terminal
marked (L) and the Yellow/Green wire to
the terminal marked
(see diagram).
3. Secure the cable by fastening the clamp
screw.
4. Close the cover of the terminal board.
Connecting the supply cable to the mains
Install a standardised plug corresponding to the load indicated on the data
plate (see table).
The appliance must be directly connected to the mains using an omnipolar
switch with a minimum contact opening of 3 mm installed between the
appliance and the mains. The switch must be suitable for the charge indicated
and must comply with current electrical regulations (the earthing wire must not
be interrupted by the switch). The supply cable must be positioned so that it
does not come into contact with temperatures higher than 50°C at any point
(the back panel of the oven, for example).
!
The installer must ensure that the correct electrical connection has been
performed and that it is fully compliant with safety regulations.
N