background image

2 of 15

Service Manual UK

Indesit

 

Company

English

HEALTH AND SAFETY

For the servicing of refrigeration products, containing Isobutane R600a refrigerant.
These instructions are in addition to any other Company procedures already published.

Published primarily for Indesit Company engineers working in the UK or Southern Ireland, 
for which these instructions are MANDATORY.

1.

Only engineers who have been trained on the safe handling of Isobutane R600a refrigerant are 
authorised to transport, store or carry out system repairs.

2.

This manual is not intended as a comprehensive repair/maintenance guide to the appliance.

3.

Must only be used by suitably qualified persons having technical competence, applicable 
product knowledge, suitable tools and test equipment.

4.

Servicing of electrical appliances must be undertaken with the appliance disconnected 
(unplugged from the electrical supply).

5.

Servicing must be preceded by earth continuity and insulation checks, plus refrigerant leak 
detection.

6.

Personal safety precautions must be taken to protect against accidents caused by sharp edges 
on metal and plastic parts.

7.

After servicing, the appliance must be rechecked for electrical safety.

8.

Smoking, naked flames, or operating gas and/or electrical equipment (including cordless power 
tools) are forbidden within the storage area, working area and vehicles used to transport 
Isobutane.

9.

The carrying case for the scales and refrigerant must display a red flammability label
Part Number 8100063 that should be visible and readable at all times.

10. The vehicle and storage area must be ventilated as far as is reasonably practicable and the 

aluminium case kept out of direct sunlight. The storage temperature of Isobutane should not 
exceed 50°C.

11. The vehicle transporting Isobutane (R600a) refrigerant must display a Red Flammable Gas 

warning sticker (Part Number 8100063).

12. Engineers should not wear clothes that are liable to cause static discharge ('electrostatic 

sparking').

13. Avoid working in small rooms.

14. Do not work in cellars.

15. Whenever possible move the appliance into a larger open area away from possible ignition 

sources.

16. Request the customer to turn off all other electrical and gas appliances in the near vicinity of the 

repair and note that it is done. 
Customers should be advised to restrict activity within the near vicinity for a short time.

17. Isobutane refrigerant must be vented to atmosphere, (outside of the premises e.g. via open 

window through the clear plastic hose supplied).

18. Isobutane is heavier than air and must not be vented within 3 metres of the following: sewer 

cover, cellar, drain or any similar construction lower than ground level, boiler air inlet/outlet, or 
near any possible source of ignition.

continued...

Summary of Contents for RZ150G

Page 1: ...Company UK Ltd 2007 Reg Office Peterborough PE2 9JB Registered in London 106725 Service Information HOTPOINT FREESTANDING FREEZERS Model Comm Covered Code RZ150P 44354 RZ150G 44355 5407383 Issue 1 Ma...

Page 2: ...dless power tools are forbidden within the storage area working area and vehicles used to transport Isobutane 9 The carrying case for the scales and refrigerant must display a red flammability label P...

Page 3: ...t aluminium canister placed in an upright position on the weighing scales provided 4 All used canisters must be a returned as scrap and therefore left out for the driver to collect and return for disp...

Page 4: ...Bruto Brut Compr Kompr Syst R 134 a kg 0 090 Gross Bruto Brut 340 Net Util Utile Gross Bruto Brut Freez Capac Poder de Cong 75 Made in 13918 Test P S I Pressure HIGH 235 LOW 140 kg 24 h 4 0 Class Cla...

Page 5: ...ic design so defrosting is actioned manually When the user defrosts the freezer the defrost water drains into the liner base and is channelled to a drain hole exiting through a spout moulded into the...

Page 6: ...band models 40dB Climate Class Rating Plate A band SN N ST 10 C to 38 C Refrigeration Type Static Wire On Tube WOT DIMENSIONS WEIGHT Models RZ150 Height 1500 mm Width 600 mm Depth 655 mm Weight Gross...

Page 7: ...uency 50 Hz Absorption Current Normal Operation 0 7 Amps COMPRESSOR WINDING Manufacturer JIAXIPERA Type I D ZBT1114CY Winding Resistance Start 16 0 Run 13 3 Refrigerant Grams R600a Refer to the applia...

Page 8: ...OF APPLIANCE TEMPERATURE CONTROL PANEL APPLIANCE INTERIOR SUPER FREEZE Button SUPER FREEZE Indicator Lamp ALARM Indicator Lamp TEMPERATURE Control Knob POWER Indicator Lamp FREEZER and STORAGE Compart...

Page 9: ...9 of 15 Indesit Company Service Manual UK English NOTES...

Page 10: ...anual Read the instructions on the next page fully and refer to the diagrams below before carrying out the door reversal Also before commencing the door reversal you will require the left door closure...

Page 11: ...xing plate Transfer them to the other side Remove the hinge pin from the right hand side of the hinge and retain until the plinth is in place Insert the plinth blanking plate supplied with the applian...

Page 12: ...ed 4 Brown Thermostat 3 5 Black Thermostat 4 6 Green Yellow Earth 1 Not Used 2 Blue Neutral 3 Not Used 4 Brown Live 5 Black Compressor Overload 6 Green Yellow Earth Yellow Super Freeze Switch 3 THERMO...

Page 13: ...erminal 1 and Control Harness Plug 4 4 CONTROL PANEL INDICATOR LAMPS Alarm Indicator Lamp Red Thermostat 6 Blue Neutral Link to Power Indicator Lamp Blue Control Harness Plug 2 Power Indicator Lamp Br...

Page 14: ...it Company English THEORETICAL WIRING DIAGRAM ELECTROLUX ACC ZEM JIAXIPERA COMPRESSORS OVERLOAD COMPRESSOR SUPER FREEZE INDICATOR LAMP POWER INDICATOR LAMP CAPACITOR if fitted SUPER FREEZE SWITCH ALAR...

Page 15: ...anual UK English PARTS and ACCESSORIES To order parts and accessories contact our National Mail Order Parts Hotline 08709 077 077 Monday to Friday 8 00am to 5 30pm Saturday 8 30am to 12 00 noon or onl...

Reviews: