9 of 49
Service Manual UK
Indesit
Company
English
In order to ensure adequate ventilation, the back panel of the cabinet unit must be removed.
Installing the oven so that it rests on two strips of wood is preferable. If the oven rests on a continuous,
flat surface, there must be an aperture of at least 45 x 560 mm.
The panels of the adjacent cabinets must be made of heat resistant material. In particular, cabinets
with a veneer exterior must be assembled with glues which can withstand temperatures of up to
100°C.
In compliance with current safety standards, contact with the electrical parts of the oven must not be
possible once it has been installed.
All parts which ensure the safe operation of the appliance must be removable only with the aid of a
tool.
Centring & Fixing - Fig. 3
Secure the appliance to the cabinet:
•
Open the oven door.
•
Pull off the rubbers side gaskets until
the 2 fixing holes are exposed.
•
Fix the oven to the cabinet using the
2 wood screws.
•
Reposition the 2 gaskets.
560 mm.
45 mm.
Fig. 2
Fig. 3