1
Errors and technical changes reserved · Hotset GmbH, Hueckstraße 16, 58511 Lüdenscheid, Germany · 10/2021 SM
hotcontrol temperature controller C 148
Rapid commissioning
The temperature controller is preconfigured
at the factory for the operation of
a regulation zone using a pre-configured
heating element and a thermocouple.
The commissioning of the control zone can
therefore be executed in only a few steps.
Caution:
Commissioning may only be executed
by specialist personnel!
The Symbol calls attention to an
operating procedure, practice, or the
like, which, if not correctly performed
or adhered to, could result in personal
injury or da mage to or destruction of
part or all of the product and system.
Do not proceed bey ond a warning
symbol until the indicated conditions
are fully understood and met.
Step 1: Electrical connection
n
Connect sensor (here thermocouple) between terminals 5 (+) and 6 (-).
n
A solid state relay (SSR) is used as a power controller.
Observe the heating output to be connected during the selection of the SSR.
n
Connect the control of the solid state relay
to terminals 9 (+) and 10 (-) at the controller.
n
Connect the heating to the supply voltage and solid state relay.
Use a super-fast fine-wire fuse or a super-fast circuit breaker
to protect the heating circuit.
n
Connect the supply voltage of the controller via terminals 7 and 8 (here 230 VAC).
Please also add a fuse here.
EN