GENERAL INFORMATION

Your 

HOT SPRING

 spa has been designed to provide years of trouble-

free use. As with any appliance, problems may occasionally occur 

that require the expertise of a qualified service person. Though such 

simple repairs as resetting a GFCI switch or breaker, or resetting a 

high limit thermostat may not require a service call, they may indicate 

that a more serious condition exists. These conditions may require an 

experienced service person. Before calling for service, please refer to 

the Troubleshooting Guide. Always retain your original sales receipt for 

future reference.

GFCI AND HIGH LIMIT THERMOSTAT

If your spa fails to operate at any time, first check the power supply to 

the spa.
Check each of the GFCI breakers in the subpanel. If a GFCI has tripped, 

reset it. If it will not reset, this may be an indication of a ground fault 

(short circuit) within the electrical components. Contact an Authorized 

Service Technician for a complete diagnosis.
If upon checking the GFCI’s you find that they have not tripped, check 

the house breaker panel and ensure the main breaker for the electrical 

circuit supplying the spa has not tripped. If it has, this is an indication 

that the circuit was either overloaded or a ground fault exists between 

the breaker panel and the spa receptacle or subpanel. Contact a 

qualified electrician.
If upon checking the main house breaker and spa GFCI’s you find no 

failures, check the high limit thermostat. To check it, simply turn off 

power to the spa for 30 seconds. This will automatically reset the high 

limit thermostat if it has tripped. If the spa energizes once you turn the 

power back on, this indicates reduced water flow through the heating 

system. Tripping of the high limit thermostat is normally a result of 

one or a combination of these problems. 1) clogged filter cartridge(s), 

2) blockage within the system plumbing, 3) a non-functioning heater 

circulation pump, 4) power was not disconnected from the spa before it 

was drained, 5) an air lock in the plumbing lines. (The Power Indicator 

on the front of the spa’s control panel will also be blinking if the high limit 

thermostat circuit has tripped.)
If the spa does not function after tripping and resetting the GFCI’s or 

resetting the high limit thermostat, then the problem should be referred 

to an Authorized Service Technician. Refer to the Heater section if the 

spa operates but does not heat, or refer to the Troubleshooting Guide 

for additional service information.

NO-FAULT

 HEATER AND 

INTEGRATED PRESSURE SWITCH

Watkins Manufacturing Corporation unconditionally warrants the 

NO-FAULT

 heater against any failure that would require replacement. 

This warranty’s duration is equal to the time period identified in the 

Component Warranty. This warranty defines unconditional as warranty 

coverage without exception provided that the component has failed to 

operate properly within the spa’s system. This means that conditions 

that would normally invalidate the limited warranty, such as water 

chemistry damage, do not apply to the 

NO-FAULT

 heater.

It is important to note that the 

NO-FAULT

 heater is protected by both the 

heater high limit thermostat circuit and the integrated pressure switch. 

The causes of heater high limit tripping are discussed in the previous 

section.

If the spa is not heating, the red and green lights are blinking, but 

the pump and light are operating, then the pressure switch may be 

open. Opening of the pressure switch is normally a result of one or a 

combination of these problems:
1.  A clogged filter cartridge 
2.  Blockage within the system plumbing 
3.  Power was not disconnected to the spa before it was drained
4.  An air lock in the plumbing lines
5.  Circulation pump not properly working 
Once the problem has been identified and corrected the pressure switch 

will close which will energize the heater.

SILENT FLO

 5000 CIRCULATION 

PUMP AND CIRCULATION PUMP 

THERMAL CUT-OFF

The 

HOT SPRING

 

SILENT FLO

 5000 circulation pump is a dedicated, 

water cooled, energy efficient, quiet pump that provides continuous 

filtration for the spa. Since the 

SILENT FLO

 5000 pump is water cooled, 

it is equipped with a thermal cut-off to prevent the pump from being 

damaged by running hot when water is not present. 
Reset the circulation pump’s thermal cut-off by disconnecting power to 

the spa and allowing the pump to cool.
Tripping of the thermal cut-off is normally the result of one or a 

combination of these problems: 1) clogged filter cartridge(s), 2) blockage 

within the system plumbing, 3) power was not disconnected to the spa 

before it was drained, or 4) an air lock in the plumbing lines. Once the 

problem has been identified and corrected the pump thermal cut-off will 

be able to be reset which will allow it to operate normally.

MISCELLANEOUS SERVICE 

INFORMATION

The control and high-limit thermostats are equipped with electronic 

sensors that are connected to the spa’s plumbing. Never cut or kink the 

wires that connect the sensors to the thermostats within the control box.
The jet pump is equipped with a thermal overload cutoff switch that is 

designed to protect the pump from overheating. If the pump shuts itself 

off in an older spa, it could indicate failure of the pump motor bearings. If 

the pump shuts itself off in a new spa, it is usually the result of one or a 

combination of the following factors:
•  Thermal overload: Although mass-produced, not all thermal overload 

cutoffs are exactly the same. Some are more sensitive than others and 

will shut the pump off at lower temperatures.

•  High temperature: All 

HOT SPRING

 spa models are equipped with a jet 

pump shroud that vents the heat generated by the pump motor to the 

outside of the equipment compartment, and back into the spa water. If 

the vent is blocked by masonry, grass or debris, overheating of the jet 

pump may occur. Once the pump motor has cooled sufficiently and any 

blockage has been removed from the vent opening, the jet pump can 

be restarted.

•  Friction: Sometimes the moving parts of a new pump are tight enough 

to cause heat build-up due to friction. After a normal break-in period, 

the pump will run cooler.

•  Improper wiring: If the spa is connected with an extension cord, and/

or the house wiring is undersized, the pump may starve for voltage and 

therefore may draw more amperage and generate excessive heat.

Service Information

Summary of Contents for Envoy NXT

Page 1: ......

Page 2: ...change specifications or design without notification and without incurring any obligation Important In most cities and counties permits will be required for the installation of electrical circuits or the construction of exterior surfaces decks and gazebos In addition some communities have adopted residential barrier codes which may require fencing and or self closing gates on the property to preve...

Page 3: ...IONAL 16 MUSIC SYSTEM SCREEN OPTIONAL 16 LIGHTS CONTROL SCREEN 17 DOCKING TRAY FUNCTION BUTTONS 17 JET MENU GRANDEE NXT MODEL GGN JET SYSTEM MENU 18 ENVOY NXT MODEL KKN JET SYSTEM MENU 19 JETSETTER NXT MODEL JJN JET SYSTEM MENU 20 SPA CARE AND MAINTENANCE DRAIN REFILL INSTRUCTIONS 21 PREVENTION OF FREEZING 21 FILTER SYSTEM 22 FILTER CARTRIDGES REMOVAL CLEANING 22 CARE OF THE SPAPILLOWS 22 CARE OF ...

Page 4: ...o not attach an external antennae to a spa audio system unless installed by a licensed electrician in accordance withArticle 810 of the National Electric Code ANSI NFPA70 WARNING To reduce the risk of electrical shock replace a damaged cord immediately Failure to do so may result in death or serious personal injury due to electrocution Your spa is provided with a Ground Fault Circuit Interrupter G...

Page 5: ...rt rate blood pressure and circulation Persons taking medications which induce drowsiness such as tranquilizers antihistamines or anticoagulants should not use the spa HEALTH PROBLEMS AFFECTED BY SPA USE Pregnant women should consult a physician before using spa Persons suffering from obesity or with a medical history of heart disease low or high blood pressure circulatory system problems or diabe...

Page 6: ...n the Troubleshooting section If you are not able to resolve the problem contact your authorized Hot Spring dealer Many problems can easily be diagnosed over the telephone by an Authorized Service Technician SPA SHELL Your HOT SPRING spa has an acrylic shell Stains and dirt generally will not adhere to your spa s surface Asoft rag should easily remove most dirt Most household chemicals are harmful...

Page 7: ...n the entire length of your back 12 The Luminescense Multi Color Four Zone Lighting system you can individually control each zone underwater bartop pillows and water features The light shown is used underwater 13 The BellaFontana water feature creates three arcs of dancing water 14 Pillow Most spas come with one or more pillows 15 Spa Filter provides 100 No Bypass filtration all water passes throu...

Page 8: ... are not adjustable Turn the faceplate to increase and decrease the jet pressure HYDROSTREAM JET The HYDROSTREAM jet is a mid size hydromassage jet that delivers a great massage to the feet back and shoulder areas Turn the faceplate to increase and decrease the jet pressure WATER FEATURE GRANDEE and ENVOY spas are equipped with a BELLAFONTANA water feature This water feature can be turned on or of...

Page 9: ...tional as indicated by strong non surging jets priming of the spa is complete to shut the jets off Weak or surging jets are an indication of a low water level condition or clogged filter cartridges IMPORTANT Be sure the COMFORT CONTROL Levers see illustration in Spa Features section are open by turning each one clockwise and checking to see that the SMARTJET lever is pointing in the 3 o clock posi...

Page 10: ...at 100 ppm then spa water pH at between 7 4 and 7 8 using a FRESHWATER 5 way test strip IMPORTANT Make sure you adjust your Total Alkalinity first as an out of balance condition will affect your ability to adjust the pH correctly and will prevent the sanitizer from operating effectively The spa is ready for use when the spa water has circulated through each SMARTJET lever operating position and th...

Page 11: ... protect you and your spa when used correctly they can be hazardous in concentrated form Always observe the following guidelines Allow only a responsible person to handle spa chemicals Keep them out of the reach of children Accurately measure the exact quantities specified never more Do not overdose your spa Handle all containers with care Store in a cool dry well ventilated place Always keep chem...

Page 12: ... reading is between 7 2 7 8 To lower the pH level use FRESHWATER pH Alkalinity Down sodium bisulfate To raise the pH level use FRESHWATER pH Alkalinity Up sodium carbonate Water Conditioners Spa fill water varies from location to location and user to user therefore it is important to consult with your dealer for an appropriate program a VANISHING ACT High levels of calcium and some minerals can be...

Page 13: ...ren present ACE SALT WATER SANITIZING SYSTEM OPTIONAL The ACE Salt Water Sanitizing System converts water and sodium chloride salt into chlorine sanitizer The ACE is compatible with chlorine based systems and chemicals Although the system is reduced maintenance it is not automatic It is important that the user regularly tests and balances the water A calcium hardness of 50 ppm is recommended to ex...

Page 14: ...in the ACE Owner s Manual LONG TIME PERIODS 5 14 DAYS Prior to leaving 1 At least one day before you leave set the temperature to its lowest level This setting should represent an approximate water temperature of 80 F 27 C IMPORTANT Spa water oxidizers such as sodium dichlor chlorine maintain their level of effectiveness substantially longer in warm water 80 F 27 C than in hot water 101 F to 104 F...

Page 15: ...iodine and astatine MPS Monopersulfate is the non chlorine oxidizer used with the FRESHWATERAg silver ion purification system Not a sanitizer Nitric Acid The formulation of nitric acid a highly corrosive chemical is a byproduct of the ozone generating process Nitric acid is produced in very small quantities and is readily dissolved in the water stream with ozone Oxidizer The use of an oxidizing ch...

Page 16: ... inside the Home screen is the actual temperature of the spa water Home Screen Functions Home Screen Features Temperature Control Status Indicators NOTE The wireless remote will revert back to the Home screen after 45 seconds of non use in any other screen Home Screen Functions Power Button Press this icon to turn jets on high and all lights on blue if both are currently off or will turn all jets ...

Page 17: ...s been used the last temperature value set by the user will be stored in memory If power is disconnected from the spa it will automatically revert to the last set temperature when power is reapplied Press to raise set temperature of spa Press and hold to raise the temperature continuously Press to lower set temperature of spa Press and hold to lower the temperature continuously MEMORY SCREEN Press...

Page 18: ... will remain off for eight hours The circulation pump and heater will automatically shut down for the same eight hours every day until the Summer Timer is deactivated It is recommended to activate the Summer Timer in the morning so that the spa is off during the hottest part of the day and so that the circulation pump will start up again in the evening when you are ready to enjoy the spa Press ON ...

Page 19: ...ay a music player with volume control and a Music Source selection box Press to turn the Music system Off The player functions consist of Track Down Play Pause and Track Up Press or to decrease or increase the volume Press to display the Select Music Source screen Press on the new desired Music source iPOD This music source requires the wireless iPOD Dock only available from your HOT SPRING dealer...

Page 20: ...lected light zone Press the multicolored box to turn color wheel on for selected light zone If more than one zone uses the color wheel the colors will automatically synchronize Press the color wheel a second time to stop the color wheel at a desired color DOCKING TRAY FUNCTION BUTTONS In the event the remote is not nearby you can still operate the Jets and Lights by pressing the buttons located in...

Page 21: ...MOTO MASSAGE DX jet b 8 directional PRECISION jets c 1 directional hydromassage jet d 1 Water Feature e 1 JETSTREAM jets JET PUMP 1 JET SYSTEM 1 Right SMARTJET lever in position a 1 MOTO MASSAGE DX jet b 10 directional PRECISION jets c 2 SOOTHINGSTREAM jets JET PUMP 1 JET SYSTEM 2 Right SMARTJET lever in position a 1 MOTO MASSAGE DX jet b 8 directional PRECISION jets c 4 directional PRECISION jets...

Page 22: ...onal PRECISION jets e 4 directional PRECISION calf jets f 2 HYDROSTREAM jets JET PUMP 2 JET SYSTEM 1 Right SMARTJET lever in position a 4 HYDROSTREAM jets b 2 SOOTHINGSTREAMjets c 1 JetStream jet d 1 Water Feature JET PUMP 2 JET SYSTEM 2 Right SMARTJET lever in position a 2 dual port rotary jets b 2 directional hydromassage jets c 4 directional PRECISION jets d 2 SOOTHINGSTREAMjets e 1 JETSTREAM j...

Page 23: ...dual port rotary jets 1 directional hydromassage jet b 4 directional PRECISION jets c 4 HYDROSTREAM jets d 1 MOTO MASSAGE DX jet JET SYSTEM 1 SMARTJET lever in position a 1 JETSTREAM jet b 4 HYDROSTREAM jets c 4 directional PRECISION jets d 1 MOTO MASSAGE DX jet e 4 directional PRECISION calf jets a b c d a b c e b d ...

Page 24: ... if that is an option for you PREVENTION OF FREEZING Your spa has been designed and engineered for year round use in any climate In some areas extremely cold temperatures below 10 F 12 C combined with strong wind may cause partial freezing of the jet pump even though the water inside the spa remains at the selected temperature The energy efficiency of the spa may also decrease during these cold pe...

Page 25: ...ach cleaning will help to extend their service life IMPORTANT The frequency and duration of use and the number of occupants all contribute to determining the appropriate time between filter cleanings More use means that more frequent filter cleanings are required Failure to maintain the cartridges in a clean unobstructed manner will result in reduced water flow through the heater assembly that may...

Page 26: ...HD consists of simply spraying the cabinet with a mild soap and water solution to remove any stains and residue Do not rub the EVERWOOD HD with an abrasive material or use abrasive cleaners as this may damage its surface CARE OF THE SPA COVER WARNING The cover is a manual safety cover that meets or exceeds all prevailing requirements of ASTM 1346 91 for spa safety covers when installed and used co...

Page 27: ... the cover just above the skirt Gently push do not lift with both hands towards the opposite rear corner of the cover diagonally As the cover opens the gas springs will allow the cover to come to a gentle stop b For the UPRITEretractable cover system Simply lift the cover at its center hinge allowing it to move to the back of the spa and to rest gently there c For the LIFT N GLIDEretractable cover...

Page 28: ...n electrical subpanel containing two GFCI breakers is included with each 230 volt spa We recommend that this subpanel be used to supply power to the spa The subpanel requires a 50 amp single phase 230 volt four wire service two line one neutral one ground The grounding conductor must not be less than 10AWG Refer to local codes and to NEC 250 122 table Mount the subpanel in the vicinity of the spa ...

Page 29: ...xceed 50 FEET H2 6 7 GRANDEE NXT GGN ENVOY NXT KKN 230 volt permanently connected models Page 26 System Ground Terminal GRD IMPORTANT THE EXACT PHYSICAL LOCATION OF THE TERMINALS ON THE GFCI BREAKER WILL VARY BETWEEN MANUFACTURERS CONNECTING THE HOT WIRE TO THE NEUTRAL TERMINAL WILL CAUSE IRREVERSIBLE DAMAGE TO THE CONTROL BOX Refer to NEC 250 122 table PROVIDED WITH HOT TUB IMPORTANT ALL WIRING S...

Page 30: ... heater It is important to note that the NO FAULT heater is protected by both the heater high limit thermostat circuit and the integrated pressure switch The causes of heater high limit tripping are discussed in the previous section If the spa is not heating the red and green lights are blinking but the pump and light are operating then the pressure switch may be open Opening of the pressure switc...

Page 31: ... and in direct exposure to sunlight this may cause solar heating distress in warm weather regions These are considered abuses and may invalidate this warranty Acts of nature and damage caused by animals rodents and insects are considered abuses and are not covered under this warranty Operation of the spa does not mean use of the spa Watkins Manufacturing Corporation does not recommend using the sp...

Page 32: ...hut Down mode Battery is not recharging Turn power to spa on Place remote control back into Docking tray Press touchscreen and wait for 40 seconds Contact your authorized HOT SPRING Dealer Remote has intermittent response when inside the 30 usable range Signal Interference from outside source Change channel on remote by pressing the Lights button on the DOCK until dock buttons flash to display a c...

Page 33: ...OT Remove Screws Grab both ends of clip and rotate downward 3 Grab panel on bottom edge and lower Set panel on ground go to Step 4 4 Disconnect logo light wire from back side of door panel Remove panel from spa and place in cool shaded place Use the following instruction to remove the front door panel below the docking station When replacing the door reverse the order making sure the Logo is seate...

Page 34: ...60 lbs 2 250 kg 110 lbs per sq foot 230 volt 50 amp Single phase GFCI protected circuit JETSETTER NXT Model JTN Seats 3 Adults 5 5 x 7 0 1 65m x 2 13m 33 84 cm 195 square feet 6 000 210 gallons 800 liters 480 lbs 220 kg 2 755 lbs 1 260 kg 95 lbs per sq foot 230 volt 50 amp Single phase GFCI protected circuit WARNING Watkins Manufacturing Corporation suggests a structural engineer or contractor be ...

Page 35: ... electrical components ozone tubing check valve injector corona discharge cell and exterior housing of the FRESHWATER III corona discharge ozone purification system against defects in material and workmanship for one year Hot Spring Highlife Everwood Moto Massage SpaStone FreshWater and No Fault are trademarks of Year Wireless Remote Control Battery Warranty Watkins warrants the battery in the wir...

Page 36: ...poration All Rights Reserved Highlife Hot Spring Moto Massage DX FootWell Grandee Envoy Jetsetter Jet Cluster SmartJet Comfort Control No Fault IQ 2020 Wavemaster Silent Flo 5000 SoothingStream JetStream Precision Everwood CoverCradle UpRite Lift n Glide EverFresh Clean Screen ACE Vanishing Act FreshWater FreshWaterAg Tri X HydroStream Luminescence BellaFontana are trademarks of Watkins Manufactur...