background image

Page 13

Operating Instructions

S

tandard

 lcd c

ontrol

 P

anel

 

The control panel provides a quick visual check of the spa’s status and 

allows the user to set the temperature, activate the jets & lights, lock the 

temperature and/or spa functions. Other optional functions may also be 

available depending on the spa model and accessory equipment that has 

been installed into the spa. The Control panel has eight buttons.  

HARD BUTTONS

The four labeled outer buttons are referred to as "Hard buttons".  These 

buttons are fixed and their functions do not change.

JETS -

 If jet pump indicator light is off and JETS hard button is pressed, 

the 1st jet pump function will activate and the Control panel display will 

advance to the Jets menu.
If jet pump indicator light is on and the JETS hard button is pressed while 

in any screen other than the Jets menu, the jets pump function does not 

change, only the Control panel screen will change to the Jets menu.

LIGHTS

 - If lights are off, press LIGHTS hard button from any screen to 

turn on the Underwater lights (only) and display the Underwater Lighting 

menu. When LIGHTS hard button is pressed in the Underwater Lighting 

menu with the underwater lights on, it will cycle the light intensity for the 

underwater lights. If underwater lights are on, initial press of LIGHTS hard 

button will not change light setting but will access Underwater lighting 

menu.

OPTIONS

 - Transitions to the Options screen to access temperature and 

setup menu

BACK

 - Goes back one menu. In Home screen Hold BACK button until 

screen rotates 180° to view from inside spa. Repeat to reverse.

SOFT BUTTONS

The four inside buttons are referred to as "soft buttons". Pressing a soft 

button will activate the function on the control panel screen closest to that 

button. The control panel display lets you know you’ve pressed a button 

and that the selected function has been performed. After a period of non-

use (45 seconds) the display will go back to the Home screen where the 

screen will remain on for several minutes before going into sleep mode. 

Pressing any button will wake up a sleeping display.

INDICATOR ICONS

The indicator icons can only be seen on the Home Screen. They are 

visible whenever the icons function is active.

 

READY Indicator:

 The READY indicator icon is displayed 

when the spa water temperature is within 1°C (2°F) of the set 

temperature, and will turn off when the temperature is outside of that 

range. If you increase or decrease the temperature setting of the spa, 

the READY indicator icon will turn off until the water temperature 

reaches the acceptable range for the new temperature setting. A 

flashing READY indicator icon means a problem may exists with the 

temperature sensor (see Troubleshooting section for more information)

 

Spa Light Indicator:

 The Spa Light indicator icon is displayed 

when any light inside the spa is on. The indicator will remain 

solid as long as any light is activated. Spa Light indicator flashes 

whenever the color wheel is on.

 

Spa or Temperature Lock Indicator:

 The Spa or 

Temperature Lock indicator icon is displayed when either the 

Spa Lock, Temperature Lock or both is activated. Lock indicator icon 

does not flash.

 

Jet Pump Indicator:

 The Jet Pump indicator icon is displayed 

whenever a jet pump is on. The Jet Pump indicator icon will 

flash whenever the spa is in the ten-minute clean cycle.

 

Summer Timer Indicator:

 The Summer Timer indicator icon 

is  displayed when the summer timer is set to ON. In the 

summer timer mode, the heater and circulation pump cycle are off for 

eight hours. The Summer Timer indicator icon will not flash.

 

Water Care Indicator:

 The Water Care indicator icon is 

displayed whenever a water care device is detected in the 

system and the water care system is operating correctly. The icon will 

flash if the water care system requires attention.

 

POWER Indicator:

 The POWER indicator icon is displayed 

when the spa is properly supplied with power. It also provides 

a diagnostic function–a flashing Power indicator icon indicates that the 

heater high limit has tripped, meaning that either the spa water is above 

its acceptable temperature range, or a malfunction has occurred within 

the spa (such as low circulation due to clogged filters). An ‘off’ power 

indicator icon means that there is a problem with the spa control box or 

the power supplied to the spa (see Troubleshooting section for more 

information).

OPTION SCREEN

The Option screen is an intermediate 

screen that gets you to various 

optional settings.
Press the OPTIONS hard button 

on the control panel to display the 

Options screen. 
Press the Soft button next to 

the descriptions to access the 

description's screen.

IMPORTANT

: Audio and ACE Water Care will only be displayed on your 

Options screen if your spa is equipped with these features.

JETS  

Hard button

Soft buttons

Indicator Icons

Control panel screen

LIGHTS  

Hard button

OPTIONS 

Hard button

BACK 

Hard button

Summary of Contents for LimeLight BOLT

Page 1: ......

Page 2: ...the right to change specifications or design without notification and without incurring any obligation Important In most cities and counties permits will be required for the installation of electrical...

Page 3: ...DRAIN REFILL INSTRUCTIONS 24 PREVENTION OF FREEZING 24 FILTER SYSTEM 25 FILTER CARTRIDGES REMOVAL CLEANING 25 CARE OF THE SPAPILLOWS 25 CARE OF THE EXTERIOR 26 CARE OF THE SPACOVER 26 COVER LIFTER SY...

Page 4: ...Corporation Do not self service audio component by opening spa door as this may expose dangerous voltage or other risk of injury Refer all servicing to qualified service personnel Do not attach an ext...

Page 5: ...ical history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a physician before using spa UNCLEAN WATER Keep the water clean and sanitized with corre...

Page 6: ...o through the steps outlined in the Troubleshooting section If you are not able to resolve the problem contact your authorized HOT SPRING dealer Many problems can easily be diagnosed over the telephon...

Page 7: ...back and can be adjusted to provide a direct stream or rotating massage 7 The Directional Hydromassage jet delivers a therapeutic massage 8 The MOTO MASSAGE DX is a moving jet It has two warm streams...

Page 8: ...required If the bearing still does not spin you will need to purchase a replacement assembly from your HOT SPRING dealer 4 To replace position the cutout at the back end of the face body downward and...

Page 9: ...Jet to shut off the jets Weak or surging jets are an indication of a low water level condition or clogged filter cartridges IMPORTANT Be sure the air Lever see illustration in Spa Features section is...

Page 10: ...the ACE system go on to the next step If the residual is less than 3 ppm superchlorinate the spa water by adding 1 teaspoons of chlorine sodium dichlor per 950 liters 250 gallons of spa water Then Ac...

Page 11: ...hemicals read the labels carefully and follow directions precisely Though chemicals protect you and your spa when used correctly they can be hazardous in concentrated form Always observe the following...

Page 12: ...lower the pH level use FRESHWATER pH Alkalinity Down sodium bisulfate To raise the pH level use FRESHWATER pH Alkalinity Up sodium carbonate Water Conditioners Spa fill water varies from location to l...

Page 13: ...ldren present ACE SALT WATER SANITIZING SYSTEM OPTIONAL The ACE Salt Water Sanitizing System converts water and sodium chloride salt into chlorine sanitizer The ACE is compatible with chlorine based s...

Page 14: ...n the ACE Owner s Manual LONG TIME PERIODS 5 14 DAYS Prior to leaving 1 At least one day before you leave set the temperature to its lowest level This setting should represent an approximate water tem...

Page 15: ...nopersulfate is the non chlorine oxidizer used with the FRESHWATERAg silver ion purification system Not a sanitizer Nitric Acid The formulation of nitric acid a highly corrosive chemical is a byproduc...

Page 16: ...ure and will turn off when the temperature is outside of that range If you increase or decrease the temperature setting of the spa the READY indicator icon will turn off until the water temperature re...

Page 17: ...ge the screen to Temp Lock Off to turn the Temp Lock and icon off HOME SCREEN The temperature displayed in the center of the Home screen is the actual temperature of the spa water If the READY icon is...

Page 18: ...w 2nd Press Jet pump 1 on High 3rd Press Both jet pumps on high speed 4th Press Jet pump 1 on Low Jet pump 2 on high 5th Press Jet pump 2 on High 6th Press All pumps off BOLT 1st press jet pump on Hig...

Page 19: ...like to change the brightness of the Control panel screen Press the OPTIONS hard button on the Control panel Press the soft button next to Set up Press the soft button next to Brightness to lower the...

Page 20: ...the spa TO ADJUST TREBLE Press SETUP SOURCE soft button to advance to the SETUP Tone Treble screen Press the soft button next to or to change the Treble between 5 and 5 Press SETUP Tone Treble soft b...

Page 21: ...ts d 1 MotoMassage DX Jet Pump 2 a 4 Combination jets b 1 Combination XL jet c 4 Direct jets d 6 Direct jets e 1 Combination jet Jet Pump 1 Jet System 2 Diverter lever in the position a 2 Combination...

Page 22: ...er Feature left wall lever must be in ON position Jet Pump 2 Jet System 1 Diverter lever in the position a 6 Direct jets b 8 Direct jets c 1 Combination XL jets d 4 Direct jets Jet Pump 2 Jet System 2...

Page 23: ...b 4 Direct Hydromassage jets in right lounge c 1 Combination XL jets in right lounge footwell d 1 Combination XL jets on front lounge wall e 2 Combination jets on front lounge wall f 4 Direct Hydroma...

Page 24: ...Jet Pump 1 a 2 Combination jets b 2 Combination jets c 4 Direct jets d 1 Combination XL jet e 1 Combination XL jet f 1 Water Feature right wall lever must be in ON position Jet Pump 2 Jet System 2 Di...

Page 25: ...Page 22 LIMELIGHT COLLECTION BOLT MODEL BLTE Jet Pump a 8 Direct jets b 4 Direct jets c 2 Combination jets d 2 Combination jets e 1 Combination XL jet A C B D E Jet Menus...

Page 26: ...Jet Pump 2 a 4 Direct jets b 1 Combination XL jet c 1 Combination XL jet d 2 Direct jets e 2 Combination jets Jet Pump 1 a 10 Direct jets b 6 Direct jets jets c 2 Combination jets d 1 Water Feature ri...

Page 27: ...s as the heater will cycle more frequently As an additional precaution against partial freezing of some of the components the equipment compartment can be insulated with an insulating kit available fr...

Page 28: ...warranty WARNING To reduce the risk of injury to persons using the spa DO NOT remove the suction fittings filter standpipes located in the filter compartment and do not sit on the filter lid in extrem...

Page 29: ...cover that meets or exceeds all prevailing requirements of ASTM 1346 91 for spa safety covers when installed and used correctly as of the date of manufacture Non secured or improperly secured covers a...

Page 30: ...of the cover just above the skirt Gently push do not lift with both hands towards the opposite rear corner of the cover diagonally As the cover opens the gas springs will allow the cover to come to a...

Page 31: ...tional 16 amp breaker in order to operate the heater and jet pump 3 at the same time Without the additional 16 amp breaker the heater will NOT operate while jet pump 3 is on Mount the subpanel accordi...

Page 32: ...iring information Mount the subpanel according to local codes but not closer than 1 5 meters 5 feet away CONDUIT INSTALLATION INSTRUCTIONS 1 To connect the electrical service first remove the screws f...

Page 33: ...Just make sure you check the following Always put your spa on a structurally sound level surface A filled spa can weigh a great deal Make certain that the location you choose can support the weight Do...

Page 34: ...Use the level to check the level of the spa Make any necessary adjustments 9 Refer to the spa pedestal support diagram for your spa to locate the remaining leveling points each of which must now also...

Page 35: ...g electric meters Gas meters A C units Is the path clear Move away branches dog houses firewood etc If there is a 90 turn can we clear it The spa will not bend No more than 6 consecutive stairs withou...

Page 36: ...cation chart WARNING The GLEAM must not be shimmed in any manner GLEAM MODEL GLME Dimensions NOTE All dimensions are approximate measure your spa before making critical design or pathway decisions GLE...

Page 37: ...tion chart WARNING The PULSE DL must not be shimmed in any manner PULSE 89 226cm 89 226cm 3 5 9 cm 34 5 87 5 cm 38 96 5 cm 18 5 47 cm 74 5 189 cm 40 5 103 cm Bottom view Front view Upside Down View of...

Page 38: ...t found in the spa specification chart WARNING The FLAIR must not be shimmed in any manner FLAIR 84 213 5cm 84 213 5cm 3 5 9 cm 32 5 82 5 cm 36 91 5 cm 19 48 5 cm 69 5 176 5 cm 31 78 5 cm Bottom view...

Page 39: ...weight found in the spa specification chart WARNING The BOLT must not be shimmed in any manner BOLT 80 203 cm 80 203 cm 3 5 9 cm 29 5 75 cm 33 84 cm 18 5 47 cm 65 165 cm 34 86 5 cm Bottom view Upside...

Page 40: ...installed on a minimum 10 cm thick reinforced concrete pad or structurally sound deck able to support the dead weight found in the spa specification chart WARNING The GLOW must not be shimmed in any m...

Page 41: ...ply to the NO FAULT heater It is important to note that the NO FAULT heater is protected by both the heater high limit thermostat circuit and the integrated pressure switch The causes of heater high l...

Page 42: ...y maintenance and damage to the spa surface caused by leaving the spa uncovered while empty of water and in direct exposure to sunlight this may cause solar heating distress in warm weather regions Th...

Page 43: ...ative or erratic AIR CONTROL valves closed Filters clogged Open AIR CONTROL lever Clean filters Blue Logo Power indicator blinking Heater high limit thermostat tripped Disconnect power for at least th...

Page 44: ...20 kg 2 075 kg 550 kg m 2 220 240 volt 20 amp Single phase GFCI protected circuit BOLT Model BLTE Seats 4 Adults 2 03 m x 2 03 m 84 cm 6 m 2 1 500 1 100 liters 320 kg 1 740 kg 490 kg m 2 220 240 volt...

Page 45: ......

Page 46: ......

Page 47: ......

Page 48: ...LEAM MODEL GLME 12 16 PULSE DL MODEL PLSE PLSDE 12 16 FLAIR MODEL FLRE 12 16 BOLT MODEL BLTE 12 16 GLOW MODEL GLWE 12 16 2016 Watkins Manufacturing Corporation All Rights Reserved Hot Spring Limelight...