Page 15
Page 15
electrical requirements
gLeaM (ConverTed)
ImpORTaNT
: If you ever need to move or relocate your Hot spring spa, it is essential that you understand and apply these installation
requirements. your
Hot Spring
spa has been carefully engineered to provide maximum safety against electric shock. Remember, connecting the
spa to an improperly wired circuit will negate many of its safety features.
ImpORTaNT:
service Technician must reconfigure spa using the soft jumpers to allow spa heater to run concurrent with jet pump.
NOTE
: Long wiring runs may require larger-gauge wire than stated.
remove power
jumpers a from Tb-1
CaUTIonS
USE COPPER CONDUCTORS ONLY
USE SUPPLY WIRES SUITABLE FOR 75°C/167°F.
DISCONNECT ALL SUPPLY CONNECTIONS BEFORE
SERVICING.
CONNECT ONLY TO A CIRCUIT PROTECTED BY A CLASS A
GROUND-FAULT INTERRUPTER.
THESE SPAS ARE INTENDED FOR USE WITH GFCI
SUBPANEL PROVIDED.
ALL CANADIAN SPA MODELS USE #8 AWG GREEN,
GROUND.
INCORRECT WIRING WILL DAMAGE CIRCUIT BOARDS.
REFER TO THE WIRING INSTRUCTIONS INCLUDED
WITH THE SUB-PANEL FOR DETAILED WIRING
INSTRUCTIONS.