background image

13

installation

 & 

operation

 

manual

 | 

ola

 

heating

 

system

 

4.2.9  TEMPERATURE CONTROL RELAY

WARNING

!

Hazardous voltage: 

Before wiring, servicing or cleaning 

the heating system, turn off the power and follow your 
organization’s lockout and tagout procedure. Failure 
to do so could allow others to turn on the power 
unexpectedly, resulting in harmful or fatal electrical 
shock.

If the OLA heating system does not maintain the desired 

preset control temperature or signals a high-limit 

temperature fault immediately upon system start-up, 

the TCR (temperature control relay), the RTD (resistance 

temperature device), or the RTD cable may require 

replacement. To perform this troubleshooting, you  

will need:

 

Ohmmeter

1. 

De-energize the heating system. Verify fluid 

is present and flow is not restricted. Check 

temperature gauge to ensure the liquid in the tank 

is below 122 °F (50 °C).

2. 

Verify the control TCR is set correctly. Verify that 

high-limit TCR is set at least 18 °F (10 °C) higher 

than the control TCR set point.

3. 

Using the ohmmeter, measure the resistance 

between TCR terminals 

O1

 and 

O2

 

(See Fig. 8)

:

 

h

If the measured resistance is 

between 80 and 

120 ohms

 continue troubleshooting. 

Proceed  

to step 4.

 

h

If the resistance is 

lower than 80 ohms

 or  

higher than 120 ohms

,contact HOTSTART  

for further assistance.

4. 

Using the ohmmeter, test for continuity between 

TCR terminals 

O2

 and 

O3

:

 

h

If there

 is continuity

 between TCR terminals 

O2

 and 

O3

, the TCR, RTD and RTD cable are 

functioning correctly. Close control panel. 

Allow fluid to cool below high-limit preset 

temperature. Perform system start-up 

(see 

SECOIO  4

)

. If fault or temperature problems 

persist after start-up, contact HOTSTART for 

further assistance.

 

h

If there

 is no continuity 

between TCR terminals 

O2

 and 

O3

, locate connected RTD on the 

heating tank. Unscrew the RTD plug from  

RTD. 

See Table 3

.

5. 

Using the ohmmeter, touch the probes to  

RTD 

lead OS2:WHO (A) 

and 

lead OS2:RED (B)

See 

Fig. 11.

 Note the resistance. Touch the probes to 

lead OS2:WHO (A)

 and 

lead OS2:RED (C) 

to check 

for continuity:

 

h

If the resistance between RTD

 lead OS2:WHO 

(A)

 and 

lead OS2:RED (B)

 is 

between 80 and 

120 ohms

 and there 

is continuity 

between RTD 

OS2:WHO (A)

 and 

lead OS2:RED (C)

, the RTD is 

functioning properly. Replace the RTD cable.

 

h

If the resistance between RTD 

lead OS2:WHO 

(A)

 and 

ead OS2:RED (B)

 is 

not between 

80 and 120 ohms

 or there is 

no continuity 

between lead OS2:WHO (A)

 and 

lead OS2:RED 

(C)

, the RTD is malfunctioning. Replace the RTD. 

L1

L2

TB1

L3

L1

L2

L3

13

T1

T2

T3

13

MPS1

TB2

X1

2 4 6

1 3 5

7 8 9 1011121314

A1 A3

T1 T2 T3

13 14 A2-

11 12

TCR1

CONTROL

0

100

A1 A3

T1 T2 T3

13 14 A2-

11 12

TCR2

HIGH
LIMIT

0

100

A

B

L1

L2

TB1

L3

L1

L2

L3

13

T1

T2

T3

13

MPS1

TB2

X1

2 4 6

1 3 5

7 8 9 1011121314

A1 A3

T1 T2 T3

13 14 A2-

11 12

TCR1

CONTROL

0

100

A1 A3

T1 T2 T3

13 14 A2-

11 12

TCR1

HIGH
LIMIT

0

100

Figure 8. 

Control (TCR1) and 

high-limit (TCR2) TCR showing 
terminals T1, T2 and T3.

Figure 9. 

RTD leads and connectors  shown on the RTD assembly, 

TSX:WHT 

(A)

, TSX:RED (red wire) 

(B)

, TSX:RED (black wire) 

(C)

, and 

Ground 

(D)

. Disconnect wire from connector as shown.

OS2EWHO

OS2ERTD

OS2ERTD

(

W

)

 

D

A

B

C

TCR

TYPE

RTD Position

TCR1

Oil

Control

40 °C

 

Oil Tank Inlet

TCR2

Oil

High-limit

90 °C

Oil Tank Outlet

Table 3.  TCR types, default temperature settings and 
corresponding RTD positions.

Summary of Contents for OLA

Page 1: ...216348 000 rev1 INSTALLATION OPERATION MANUAL MODEL OLA OIL CIRCULATING HEATING SYSTEM FOR HAZARDOUS LOCATIONS ...

Page 2: ......

Page 3: ...r and serial number ready when contacting the warranty department COPYRIGHT Hotstart Manufacturing Inc is the owner of all trademarks and copyrightable material contained herein all rights are reserved no form of reproduction is authorized without prior written consent from Hotstart Manufacturing Inc NOTE Typical heating system identification plate Your identification plate may vary Corporate Manu...

Page 4: ...ble overcurrent limiting device Power disconnection A means to disconnect the heating system from the power supply is required HOTSTART recommends that a power switch or circuit breaker be located near the heating system for safety and ease of use Flameproof joints Flameproof joints are not intended to be repaired in the field Do not attempt to repair any flameproof joints that become damaged Bend...

Page 5: ... Prime Button 9 3 1 3 Reset Button 9 3 1 4 Pressure Temperature Gauge 9 3 1 5 Pressure Relief Valve 9 3 2 SYSTEM COMPONENTS 10 3 2 1 Motor Protection Switch 10 3 2 2 Control TCR Temperature Control Relay 10 3 2 3 High Limit TCR Temperature Control Relay 10 3 3 HEATING SYSTEM START UP 10 3 3 1 First Run Procedure 11 4 MAINTENANCE AND TROUBLESHOOTING 11 4 1 SYSTEM FAULTS 11 4 1 1 Oil Faults 11 4 2 S...

Page 6: ...iv installation operation manual ola heating system this page intentionally left blank ...

Page 7: ...ions are for reference only and are not to scale See part drawings for dimensions and specifications A local off remote switch B prime button C reset button D Heating element E Oil outlet 1 NPT F High limit resistance temperature device RTD G Heating tank H Identification plate I Control resistance temperature device RTD J Pressure Temperature gauge K Pump motor L Oil pump M Oil inlet 0 5 1 0 1 5 ...

Page 8: ... line The oil pump will continuously circulate fluid throughout the engine or compressor To maintain consistent fluid temperature the heating element will cycle on and off at the user selected temperature control point An oil check valve user supplied and installed near the oil suction port prevents backflow while the engine or compressor is operating When the engine or compressor is shut down the...

Page 9: ...ure it is completely full of fluid while in operation Pump priming Fill supply line with fluid Pump is not self priming Fluid must be present in the pump before start up Trapped air inside the pump will cause pump and seal damage Pump seal damage Do not reduce the oil supply line to an inner diameter smaller than the pump inlet pump seal damage could occur Check valve HOTSTART recommends installin...

Page 10: ...eters To minimize flow restriction HOTSTART recommends using sweeping bends or 45 fittings At a minimum size the oil supply line per the pump inlet NOTICE Do not reduce the supply line inner diameter pump seal damage will occur NOTE To maximize flow and allow the longest possible supply line install the largest practical inner diameter hose for most installations HOTSTART recommends using a hose w...

Page 11: ...CTION PORT SECTION 2 1 1 CHECK VALVE SECTION 2 1 1 ISOLATION VALVE ISOLATION VALVE OIL SUPPLY SECTION 2 1 1 OIL RETURN SECTION 2 1 2 E 2 E 1 V 2 V 3 V 1 COMPONENT DESCRIPTION V 1 USER SUPPLIED CHECK VALVE V 2 USER SUPPLIED FULL FLOW ISOLATION VALVE E 1 OIL PUMP E 2 OIL HEATING ELEMENT V 3 USER SUPPLIED FULL FLOW ISOLATION VALVE ...

Page 12: ... SECTION 2 1 1 ISOLATION VALVE OIL SUPPLY SECTION 2 1 1 OIL RETURN SECTION 2 1 2 ISOLATION VALVE CHECK VALVE SECTION 2 1 1 E 2 E 1 V 2 V 3 V 1 V 4 COMPONENT DESCRIPTION V 1 USER SUPPLIED CHECK VALVE V 2 USER SUPPLIED FULL FLOW ISOLATION VALVE E 1 OIL PUMP E 2 OIL HEATING ELEMENT V 3 USER SUPPLIED FULL FLOW ISOLATION VALVE V 4 OPTIONAL USER SUPPLIED PRV ...

Page 13: ...n Electrical hazard The heating system must be connected to a suitable protective earthing conductor The heating system s power supply must be connected to a suitable overcurrent limiting device A means of disconnection from power supply is required HOTSTART recommends that a power switch or circuit breaker be located near the heating system for safety and ease of use Reference markings on heating...

Page 14: ...utdown connection is wired NC normally closed from the factory see system wiring schematic for directions to switch to NO normally open operation TB2 3 TB2 4 Fault Signal D The fault signal will indicate a heating system shutdown triggered by either the high limit temperature control relay or the motor protection switch see SECTION 4 1 1 TB2 5 TB2 6 Motor Run Signal E A motor run signal indicates ...

Page 15: ...e than five seconds at a time NOTE The prime function is intended for use during the first run procedure see SECTION 3 3 1 or after performing maintenance on the heating system or plumbing see SECTION 4 2 3 1 3 RESET BUTTON Press the reset button to reset the pump motor protection switch without opening the control box The reset function is intended for use immediately following resolving and repa...

Page 16: ...erheating The high limit TCR uses a resistance temperature device RTD located near the tank outlet The default setting for the high limit TCR is 194 F 90 C and should always be at least 18 F 10 C higher than the control TCR set point The high limit TCR hysteresis is not used in the high limit control See Fig 7 Figure 7 OLA motor protection switch left showing stop off A and reset on B buttons To r...

Page 17: ...n the control dial on the temperature control relay TCR1 to the desired temperature setting for engine oil HOTSTART recommends a control temperature on TCR1 of 104 F 40 C The high limit temperature setting on TCR2 should be set at 194 F 90 C See SECTION 3 2 2 and SECTION 3 2 3 7 Turn the local off remote switch to remote to verify the 24 V DC remote signal connection if installed 4 MAINTENANCE AND...

Page 18: ...d contactor coil The contacts on the magnetic contactor should be inspected periodically for welding arc erosion and mechanical wear If any of these conditions exist replace the magnetic contactor HOTSTART recommends contactors be replaced every five years 4 2 5 PUMP SEAL If seal becomes worn replacement pump seals are available To ensure pump seal longevity ensure the supply lines do not restrict...

Page 19: ... below high limit preset temperature Perform system start up see SECTION 4 If fault or temperature problems persist after start up contact HOTSTART for further assistance h h If there is no continuity between TCR terminals T2 and T3 locate connected RTD on the heating tank Unscrew the RTD plug from RTD See Table 3 5 Using the ohmmeter touch the probes to RTD lead TS2 WHT A and lead TS2 RED B See F...

Page 20: ...en to ensure that the heating system is operational for start up Steps must be taken to ensure that water ingress is mitigated at all locations All plugs and caps must remain tight and a suitable cover must be provided for the system The cover must shield the system from direct rain and protect from any directed spray that may occur For any storage longer than three months desiccant bags must be p...

Page 21: ... tripped Check and reset switch If problem occurs again check motor Restart system RTD failure Check TCR and RTD See SECTION 4 2 9 RTD cable failure Check TCR and RTD See SECTION 4 2 9 Oil temperature too low Motor failure Check motor Replace if necessary Heater has been turned off and fluid is cold Allow time for the heating system to heat fluid Heating element failed Check elements for continuit...

Reviews: