background image

 Functionality (Clusters) 

 

(input 0x0000) Basic  

 

(input 0x0006) On/Off 

 

(input 0x0702) Consumption metering 

 

(input 0x0003) Identify 

 

(input 0x0004) Groups  

 

(input 0x0005) Scenes   

 

Control 

 

By pressing the button once, the power supply to the consumer is toggled. 

 

If the device is connected to a ZigBee network, use the capabilities of the corresponding 

system to monitor and control the device remotely.  

 

If the plug is bound with another ZigBee device (eg Button) follow its instructions. Most 

often, the command is sent by a single press.  

 

Indicators 

The device has two light indicators: 

Orange 

– to indicate the line is powered.  

Blue 

– for backlight (line off) and configuration status indication:  

 

FAST blinking (4 times/second) – when executing a command. 

 

SLOW blinking (once/second) – when entering a command or returning 

the result of a command. 

In case of an invalid command or configuration error, the blue LED will blink 

SLOWLY as follows: 

 

1 – wrong command. 

 

2 – the device is not part of a ZigBee network. The command could not be 

executed. 

 

3 – the device is locked. The configuration command could not be 

executed. 

 

4 – the device is part of a ZigBee network. The command could not be 

executed. 

 

5 – wrong PIN/PUK code. The command will not be executed. 

 

Summary of Contents for GMB-HAR-PL1-M02

Page 1: ...Smart metering plug Model Logical devices GMB HAR PL1 M02 1 x Smart plug User Guide version 2 0...

Page 2: ...The plug has built in overload and overheating protections which will turn off the consumer and the device will generate an Electricity failure alarm After turning on the power the device is in the of...

Page 3: ...single press Indicators The device has two light indicators Orange to indicate the line is powered Blue for backlight line off and configuration status indication FAST blinking 4 times second when ex...

Page 4: ...blue LED indicator will turn off if it is on After another 2 seconds the blue LED indicator will start blinking SLOWLY Wait until the blue LED indicator blinks the CORRESPONDING NUMBER of times NUMBE...

Page 5: ...12 Deny Allow blue backlight Network status 1 Submit network status command by pressing the button and wait for 4 blinks 2 The blue LED indicator will start blinking SLOWLY 2 times if the device is no...

Page 6: ...ed to a ZigBee network make sure the device is not locked and turn off the power for about 30 seconds When the power is restored the device will automatically start searching for a ZigBee network to j...

Page 7: ...ins locked If you enter the wrong PIN PUK code 3 times in a row the device will be locked for 1 hour During this time it cannot be unlocked even after rebooting This 1 hour is measured only when power...

Page 8: ...Disable backlight 1 Submit Enable Disable backlight command by pressing the button and wait for 12 blinks 2 If the blue backlight is off it will turn on and vice versa if it is on it will turn off Tu...

Reviews: