Initial power on

 

On power up, the device will check if it has a configured ZigBee network and: 

a.

 

If there is a ZigBee network configured, the device will start periodically trying to join it 

until it successfully joins. If you want to terminate this process, you need to execute the 

"Leave network" command. This command will reset the device to its factory default 

settings. 

b.

 

If there is no ZigBee network configured and the device is unlocked, it will make 4 

consecutive attempts to join an ZigBee network, within up to 1 minute. If the device 

does not join a ZigBee network, it can be configured later. 

* If there is no ZigBee network configured and the device is locked, it will not automatically 

try to join a ZigBee network at power up. To allow such a device to join a network, unlock it. 
 

Configuration 

To configure the device press and hold the button. After 3 seconds the blue LED 

indicator will turn off, if it is on. After another 2 seconds the blue LED indicator will start 

blinking SLOWLY. Wait until the blue LED indicator blinks the CORRESPONDING NUMBER of 

times (NUMBER OF BLINKS) for the desired command and release the button. Possible error 

indications: 

 

If a wrong or invalid command is entered, the blue LED will blink 1 time SLOWLY. 

 

If the device is not part of a ZigBee network and you execute a command related to a 

ZigBee network, the blue LED indicator will blink 2 times SLOWLY, indicating that the 

command cannot be executed. 

 

If the device is locked, the blue LED will blink 3 times SLOWLY, indicating a locked state, 

and the command will not be executed. 

 

If the device is part of a ZigBee network and you execute a command to join or form a 

network, the blue LED indicator will blink 4 times SLOWLY, indicating that the command 

cannot be executed. 

 

When wrong PIN/PUK code is entered, the blue LED indicator will blink 5 times SLOWLY. 

* When the device is in configuration mode, no other commands can be executed, but it can 

be controlled.  
 
 
 

Summary of Contents for GMB-HAR-PL1-M02

Page 1: ...Smart metering plug Model Logical devices GMB HAR PL1 M02 1 x Smart plug User Guide version 2 0...

Page 2: ...The plug has built in overload and overheating protections which will turn off the consumer and the device will generate an Electricity failure alarm After turning on the power the device is in the of...

Page 3: ...single press Indicators The device has two light indicators Orange to indicate the line is powered Blue for backlight line off and configuration status indication FAST blinking 4 times second when ex...

Page 4: ...blue LED indicator will turn off if it is on After another 2 seconds the blue LED indicator will start blinking SLOWLY Wait until the blue LED indicator blinks the CORRESPONDING NUMBER of times NUMBE...

Page 5: ...12 Deny Allow blue backlight Network status 1 Submit network status command by pressing the button and wait for 4 blinks 2 The blue LED indicator will start blinking SLOWLY 2 times if the device is no...

Page 6: ...ed to a ZigBee network make sure the device is not locked and turn off the power for about 30 seconds When the power is restored the device will automatically start searching for a ZigBee network to j...

Page 7: ...ins locked If you enter the wrong PIN PUK code 3 times in a row the device will be locked for 1 hour During this time it cannot be unlocked even after rebooting This 1 hour is measured only when power...

Page 8: ...Disable backlight 1 Submit Enable Disable backlight command by pressing the button and wait for 12 blinks 2 If the blue backlight is off it will turn on and vice versa if it is on it will turn off Tu...

Reviews: