inStallatiOn lOcatiOn
Figure 4
Figure 5
Figure 6
location - all Models
S
elect a location near the center of the space to be heated. Overflow
heat will circulate through doorways into adjacent rooms.
The furnace is to be located on an outside wall. Locate wall studs
so that wall opening will be located between wall studs. One wall
stud can be used for attachment of inside wall plate. The wall
opening required as shown in Figure 3 is a minimum diameter of
6 1/4" (159 mm). The inside wall plate and the outside wall plate are
large enough to permit a wall opening diameter of 8" (203 mm).
A template is provided in furnace carton for positioning furnace
on the wall. Also, refer to Figure 3 for positioning the furnace on
wall and for locating gas line connection.
WALL MOUNTING
PLATE
MIN 4 ½”
MAX. 12”
CASING
FRONT PANEL
To remove - pull out at top
and lift up.
WALL MOUNTING HOLES
6 1/4” DIA. MIN.
WALL OPENING
HWDV080(B)DV - 20”
HWDV181(B)DV - 24 1/2”
4”
9 1/4”
OPTIONAL GAS
INLET LOCATIONS
Figure 3
For large homes or spread-out floor plans, two or more furnaces
are recommended.
Do not
locate furnace where a door could swing over the outer
casing.
See Figure 4.
Do not
install in a closet, alcove or small hallway where the furnace
could be isolated by closing doors to the heated space.
See Figures
5 and 6.
Do not
block air circulation of furnace.
When location is selected, check the walls to make sure there are
no obstructions such as pipes, electric wiring, etc., which would
interfere with the installation of the furnace or vent pipe.