INSTALLATION OVERVIEW
WARNING: Any change to this heater or its control can be dangerous.
WARNING: Provide adequate clearances and accessibility for purposes of servicing and
proper operation.
A manufactured home (USA only) installation must conform with the Manufactured Home Construction and Safety Standard,
Title 24 CFR, Part 3280 or, when such standard is not applicable, the Standard for Manufactured Home Installations, ANSI
Z225.1.
WARNING
:
Due to high surface temperature, keep children, clothing, and furniture away. Keep burner and control com-
partments clean.
INSTALLATION OVERVIEW
WARNING
: Improper installation, adjustments, alteration, service, or maintenance can cause property damage,
personal injury or loss of life.
Installation and service must be performed by a qualified installer, service agency, or the gas supplier.
These wall furnace models are designed for direct venting through a wall. Only venting components approved for these
furnaces may be used.
This unit is to be installed on a wall from 4-1/2in to 12in (114.3mm to 304.8mm) thick.
Note: All references must be considered as if the observer is standing in front of the wall and/or appliance.
1
Mark the venting system hole location (as indicated
on page 21, box 4) and the six holes through the wall
mounting plate. Drill accordingly. Insert the four wall
anchors provided and tighten the wall mounting plate
firmly. Use special anchor fasteners if the heater is to
be installed on a wooden (hollow) wall. Line up the
two tabs on the top of the wall mounting plate with the
holes in the back of the unit. Slide the back of the unit
onto the tabs of the wall mounting plate. Secure the
back of the unit into place using two screws. Replace
casing door. The heater is now ready to receive the
venting system assembly from the opposite side of
the wall.
Note: All references must be considered as if the ob-
server is standing in front of the wall and/or appliance.
IMPORTANT: The venting system must be prop-
erly installed to ensure proper and safe opera-
tion. The venting system must also be properly
re-installed and re-sealed to ensure proper and
safe operation.