OPERATION AND TESTING
WALK TESTING PROCEDURE
The sensor will rotate from left to right and up to down. Adjust the sensor to
point in the desired direction for the sensor patterns (see
Figure 1
).
1. Set the two adjustment controls on the bottom of the sensor (see
Figure 2
)
to the following positions:
TIME - Fully counter-clockwise
LUX - Fully clockwise
The unit will now operate during daytime as well as night, illuminating the
lamp for approximately 5 seconds each time. This allows testing to be carried
out to establish the best position for the sensor.
2. Switch on the mains power. The lamp will immediately illuminate as the
unit goes through its “warm-up” period. After approximately 1 - 2 minutes
the lamp will extinguish. Try to remain outside the detection area during
the warm-up period.
3. Walk across the detection area approximately 5 metres from the unit. As
you cross a detection “zone” the lamp will illuminate. Now stand still until
the lamp extinguishes (this should take approximately 5 seconds).
4. Start moving again. As you cross each “zone” the lamp will illuminate.
5. Repeat the above, walking at various distances and angles to the unit. This
will help you to establish the detection pattern.