background image

 

For accurate barometric pressure trends, the weather 

station should operate at the same altitude for recordings 

(i.e. it should not be moved from the ground to the second 

floor of the house). When the unit is moved to a new 

location, discard readings for the next 12 hours and 

correct the height adjustment if needed   

Wrong temperature 

 

Check whether the sensor is exposed to direct sunlight.

 

 

Technical data 

 

a) Main Unit

 

 

Barometer unit: hPa / inHg 

 

Barometer pressure measuring range: 850hPa to 1050hPa   

 

Weather display: Sunny, Slightly Cloudy, Cloudy, Rainy, Storm 

 

Temperature unit: °C / °F 

 

Temperature measurement range: 

32

℉—

+122

 

(0°C to +50 °C) 

 

Indoor temperature / humidity trend and max / min function 

 

Moon phase   

 

Humidity measurement range: 20 to 95% 

 

Comfort face display 

 

Time display: 12/24 hour format 

 

Calendar: DD/MM or MM/DD 

 

Weekday in 7 languages: German, English, French, Italian, Dutch, Spanish, Danish 

 

Dual alarm with snooze function (5 minutes alarm interruption) 

 

Power supply : 3 X AAA, UM-4, LR03 1.5V batteries, DC 5.0V power adapter   

 

7 colors    back light display :RED

GREEN

BLUE

LIGHT GREEN

PURPLE

LIGHT BLUE

WHITE

 

 

 

b) Outdoor sensor

 

 

Transmission frequency: 433 MHz 

 

Transmission range: up to 30 m in open area with no obstruction 

Temperature measurement range:

4

- 140

 

(-20 °C to +60 °C) 

 

Humidity measurement range: 20 to 95% 

 

Outdoor temperature / humidity trend and max / min function 

 

Power supply: 2 X AAA, UM-4, LR03 1.5V batteries 

 
Care and maintenance   

 

 

Read carefully the manual before using this product. 

 

Do not expose the main unit to direct sunlight, extreme cold and moisture, and sudden changes in 

temperature. This would reduce the accuracy of detection. 

 

Do not place the product in locations prone to vibration and shocks 

– these may cause damage. 

 

Do not expose the product to excessive force, impacts, dust, high temperatures or humidity - these may 

cause malfunction, shorter battery life, damage to batteries and deformation of plastic parts. 

Summary of Contents for AOK-2039B

Page 1: ...peration before using the instrument Keep the manual for future reference and pass it on with the device if you pass on the device to other users NOTE Always remember to use high quality batteries cha...

Page 2: ......

Page 3: ...17 Low battery for outdoor sensor 18 Time 19 WEEKS 20 Day of week 21 Month 22 Alarm 23 Date 24 Hour of history 25 Air pressure 26 Moon phase 27 Light a b c mode 28 Outdoor temperature 29 Icy alert 30...

Page 4: ...le pass through the hole in the stand plug the power cable to the power jack and plug the power adapter into a suitable power outlet NOTE It is recommended to insert the battery as a backup power Remo...

Page 5: ...ries inserted the main unit will lose all the weather data Every time the outdoor sensor batteries are replaced the sensor will synchronize with the main unit again You must press the CH key for more...

Page 6: ...sensor You can read the data of up to 3 sensors at one weather station Use the sliding switch for each outdoor sensor to select the outdoor sensor channel Press the key CH in main unit to select a cha...

Page 7: ...er time and enter the Winter time at 2AM on the first Sunday of November Daily alarm set up Press MODE to switch to Alarm1 mode A1 and the alarm time displayed Press and hold the key MODE for 3 second...

Page 8: ...onfirm Temperature lower limit and the icon displayed press MEM or HISTORY to set the lower alert temperature Pess the key ALERT to confirm Information The clock automatically exit setting mode if no...

Page 9: ...00 m 10 m increment press SNOOZE LIGHT to confirm After setting the altitude use MEM or HISTORY buttons to set the weather forecast icon press SNOOZE LIGHT to confirm For accurate barometric pressure...

Page 10: ...health and home environment Comfortable If the indoor humidity is within 40 70 RH and the temperature within 20 28 C the icon comfortable environment will be displayed Dry If the indoor humidity is l...

Page 11: ...r shows 7S automatic cycle Manually press MODE to confirm the color and quit the automatic change mode the program does not set the automatic exit Backlight color switch RED GREEN BLUE LIGHT GREEN PUR...

Page 12: ...Italian Dutch Spanish Danish Dual alarm with snooze function 5 minutes alarm interruption Power supply 3 X AAA UM 4 LR03 1 5V batteries DC 5 0V power adapter 7 colors back light display RED GREEN BLUE...

Page 13: ...ot intended for use by persons including children whose physical sensory or mental disability or lack of experience and expertise prevents safe use unless they are supervised or instructed regarding u...

Page 14: ...s authority to operate the equipment NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designe...