54
5 Options
RoofVent
®
LKW units can be adapted to the requirements of the specific project with a series of options.
You will find a detailed description of all optional components in Section K 'Options' of this handbook.
Option
Use
ColdClimate design
For installation of the RoofVent
®
unit in areas where the fresh
air temperatures fall below –30 °C
Oil-proof design
When using the RoofVent
®
unit in applications with high oil
content in the extract air
Hygiene design
When using the RoofVent
®
unit in applications with higher
hygiene requirements (corresponds to VDI 6022)
Fans with variable air flow rate
For operation of the unit with variable air flow rate
(supply air and exhaust air)
High-pressure fan, supply air
To overcome additional external pressure drop
(e.g. from supply air ducts installed on-site)
High-pressure fan, exhaust air
To overcome additional external pressure drop
(e.g. from extract air ducts installed on-site)
Hydraulic assembly diverting
system
To facilitate hydraulic installation
Magnetic mixing valve
For continuous regulation of the heating coil (ready-to-
connect)
Fresh air silencer
For reduction of noise from the weather louvre door
Exhaust air silencer
For reduction of noise from the exhaust air grille
Supply air silencer
For reduction of noise within the room
Extract air silencer
For reduction of noise within the room
Acoustic cowl
For reduction of noise within the room (in the Air-Injector)
Actuators with spring return
As additional frost protection (close the fresh air
damper and the ER damper during a power failure)
Air outlet box
When using the RoofVent
®
unit in low-roofed halls
(instead of the Air-Injector)
Drop eliminator
To drain condensate from the plate heat exchanger onto the
roof
Condensate pump
To drain condensate from the condensate separator through
waste water pipes directly below the ceiling or onto the roof
Heating and cooling in the 4-pipe
system
Additional heating section for 2 completely separate hydraulic
circuits
Design for injection system
For installation of the RoofVent
®
unit with a hydraulic injection
system (integrated pump control)
Table C10: Availability of options for RoofVent
®
LKW
RoofVent
®
LKW
Options
Summary of Contents for RoofVent CON-9
Page 2: ......
Page 4: ...2...
Page 6: ...4...
Page 8: ...6...
Page 12: ...10 RoofVent LHW Use...
Page 40: ...38 RoofVent LKW Use...
Page 68: ...66 RoofVent twin heat Use...
Page 94: ...92 RoofVent twin cool Use...
Page 122: ...120 RoofVent twin pump Use...
Page 150: ...148...
Page 154: ...152 RoofVent condens Use...
Page 180: ...210 RoofVent LH Construction and operation...
Page 208: ...238 RoofVent LK Use...
Page 256: ...286...
Page 268: ...298...
Page 274: ...304...
Page 279: ......