INSTALLATION INSTRUCTIONS
URL Series Luminaires
9/30/2014
IMPORTANT:
WARNING:
All work should be performed by a qualified electrician.
To insure personal safety, proper grounding is req'd.
LUMINAIRE INSTALLATION:
Open the luminaire by pulling the trigger
latch toward the nose of the fixture.
Swing the lower housing (door) away
from the upper housing.
The lower housing (door) can be
removed from its hinges for easier
installation of upper housing.
Determine the size of the mounting arm. This luminaire
is designed to optimally accommodate a 2" mounting
arm. If mounting to a 1-1/4" arm, use of included
birdguard is recommended.
Loosen the fitter bolts in the upper housing.
Lift the upper housing into position in front of
the mast arm so that the mast arm enters the
opening at the rear of the housing and extends
into the fixture bewteen the fitter clamp
and the luminaire leveling steps.
Using the cast leveling steps, adjust
the luminaire to the desired mounting angle.
Fully tighten fitter clamp bolts (10-12 ft-lbs).
These instructions do not claim to cover every detail or variation in the equipment or application.
These instructions do not claim to cover every possible contingency during installation or maintenance.
Read all instructions carefully before attempting
installation. If you do not understand these
instructions, please consult your local distributor.
Disconnect power during installation and before
servicing (including relamping).
Risk of Fire.
Product is for outdoor installation and use only.
Thoroughly inspect the fixture for any freight damage;
freight damage should be reported to the delivery
carrier.
To avoid the risk of fire or shock, this fixture must be
wired in accordance with the National Electric Code
and applicable local codes or ordinances.
Compare the catalog/model number description on the
packing slip with the fixture label to assure that you
have received the correct product.
Doc. #1025-000218-000 rev.03