INSTALLATION INSTRUCTIONS
XFLE-TR Series
04/12/2018
Doc#1025-000244-001 RV0
Model number parameter list
1
Where C represents CCT variations.
Model
1
Input Voltage
Input Power
(W)
Power
Factor
Input
Current
Weight
(lbs)
Ambient rating
XFLE-C100-MV-TR Series
100 – 277VAC
50/60 Hz
100W
>0.9
1.5A
14
-40° to +40°C
-40° to 104°F
XFLE-C150-MV-TR Series
150W
1.8A
14
XFLE-C230-MV-TR Series
230W
2.5A
18
XFLE-C300-MV-TR Series
300W
3.5A
24
XFLE-C100-HV-TR Series
277 – 480VAC
50/60 Hz
100W
0.55A
14
XFLE-C150-HV-TR Series
150W
0.88A
14
XFLE-C230-HV-TR Series
230W
1.4A
18
XFLE-C300-HV-TR Series
300W
1.8A
24
Warning:
To avoid electric shock:
Be certain electrical power is OFF before and
during installation and maintenance.
Luminaire must be connected to a wiring
system with an equipment-grounding
conductor.
Warning:
To avoid the risk of fire, explosion, or electric shock, this
product should be installed, inspected, and maintained by a
qualified electrician only, in accordance with all applicable
electrical codes.
Warning:
Make sure the supply voltage is the same as the
rated luminaire voltage.
Not suitable for hazardous location use.
Do not operate in ambient temperatures above
those indicated on the luminaire nameplate.
Keep lens tightly closed when in operation.
For supply connections use wire rated for at least 90°C (194°F)
Mounting Details (inches):
For 100, 150, & 230W luminaires
For 300W luminaire