Thank you for purchasing the HOZAN F
-
66
-
S ESD
GLOVES, SMALL. With proper care
and handling, these fine instruments will provide years of trouble
-
free operation. Please
read this entire instruction manual carefully before attempting to place these instruments in
service. Please keep this instruction manual available for reference.
ESD GROVES, SMALL
(10pairs/pack)
F
-
66
-
S
1. Do not use on energized places. This
could cause a shock.
2. Do not touch liquid or hot things directly
while wearing these gloves.
Warning
Precautions
Carry out inspection periodically to ensure
that they maintain their potential.
Caution
INSTRUCTION MANUAL
16.04
1
-
2
-
12 Saiwaicho, Naniwa
-
ku, Osaka 556
-
0021, Japan
Tel : +81-6-6567-3111
F a x : +81
-
6
-
6562
-
0024
3
3
3
3
Antistatic standards
* Foundation Standard released by the Japan Accreditation Board for Conformity (RCJ).
“Standard Electrostatic Protection Requirements for Electronic Devices” (RCJS
-
5
-
1)
HOZAN’s ESD
-
safe products are controlled with reference to the Japanese
standard (RCJS
-
5
-
1*) which is based on the international standard (IEC61340
-
5
-
1).
Products which bear the “ “ mark are products to which the standard values
(see table below) apply. The “ESD Standard” listed on each of the product pages
denote the HOZAN standard for the product.
Less than 2 secs. from
initial value (Max.
1000V) to 10%
ESD
-
safe item requirements
(Excerpted from RCJS
-
5
-
1:2014)
【
【
【
【
Item
-
specific requirements
】
】
】
】
Where foot grounder and floor system are employed as personal
grounding device, the grounding resistance must be determined by the
ESD coordinator. The recommended value is 7.5 X 10
5
to 3.5 X 10
7
Ω
.
Charge decay
*2
Gloves and
finger cots
EPA ground resistance
or Resistance Rg(
Ω
) of
groundable point
Gloves and finger sacks
that satisfy the system requirements.
Using gloves
and finger cots
7.5
×
10
5
≦
Rg
<
1
×
10
12
【
【
【
【
System requirements
】
】
】
】
*2
…
Specifications
15 g
White
Fingertips: Polyurethane
coating
Others: Nylon,
Conductive yarn
(Carbon fiber)
Weight
Materials
Color (wrist)
ESD standard
Charge decay from
1000V to 100V in less
than 2 secs.
Regarding grounding
These products
show their
primary function
under being
grounded.
Please use with
wearing F
-
154
Wrist Strap and
such.
1. Always ground when use, otherwise
these do not function causing damage
to electronic components, shock to
operators or an explosion according to
circumstances.
2. Prepare a grounding line for ESD
separately from the grounding line
concerning power line. This could
cause a shock.
Warning
ground
S
Size
200 mm
OAL