Thank  you  for  purchasing  the  HOZAN  F

-

66

-

S  ESD

 

GLOVES,  SMALL.  With  proper  care 

and  handling,  these  fine  instruments  will  provide  years  of  trouble

-

free  operation.  Please 

read this entire instruction manual carefully before attempting to place these instruments in 
service. Please keep  this instruction manual available for reference.

 

ESD GROVES, SMALL 

(10pairs/pack)

 

F

-

66

-

S

 

1. Do not use on energized places. This 

 

    could cause a shock.

 

2. Do not touch liquid or hot things directly 

 

    while wearing these gloves.

 

 

Warning

    

    

Precautions

    

Carry out inspection periodically to ensure 

that they maintain their potential. 

 

 

Caution

    

INSTRUCTION MANUAL

    

16.04

 

1

-

2

-

12 Saiwaicho, Naniwa

-

ku, Osaka 556

-

0021, Japan

 

Tel : +81-6-6567-3111

   

F a x  : +81

-

6

-

6562

-

0024

 

3    

    

Antistatic standards

 

* Foundation Standard released by the Japan Accreditation Board for Conformity (RCJ).

 

  

“Standard Electrostatic Protection Requirements for Electronic Devices” (RCJS

-

5

-

1)

 

HOZAN’s  ESD

-

safe  products  are  controlled  with  reference  to  the  Japanese 

standard (RCJS

-

5

-

1*) which is based on the international standard (IEC61340

-

5

-

1).

 

Products which bear the “            “ mark are products to which the standard values

 

 (see  table below) apply. The “ESD Standard” listed on each of the product pages 

denote the HOZAN standard for the product.

 

Less than 2 secs. from 

initial value (Max. 

1000V) to 10%

 

ESD

-

safe item requirements 

 

(Excerpted from RCJS

-

5

-

1:2014)

    

Item

-

specific requirements

    

Where foot grounder and floor system are employed as personal 

grounding device, the grounding resistance must be determined by the 

ESD coordinator. The recommended value is 7.5 X 10

5

 to 3.5 X 10

7

 

Charge decay

 

*2

 

 

Gloves and 

finger cots

 

EPA ground resistance 

 

or Resistance Rg(

Ω

) of 

groundable point

  

Gloves and finger sacks 

 

that satisfy the system requirements.

 

Using gloves 

and finger cots

 

7.5

×

10

5

Rg

 

1

×

10

12

 

System requirements

    

*2

… 

    

Specifications

    

15 g

 

White

 

Fingertips: Polyurethane 

 

                  coating

 

Others: Nylon, 

 

             Conductive yarn 

 

            (Carbon fiber) 

 

Weight

 

Materials

 

Color (wrist)

 

ESD standard

 

Charge decay from 
1000V to 100V in less 
than 2 secs.

 

    

Regarding grounding

    

These products 

show their 

 

primary function 

under being 

grounded.

 

Please use with 

wearing F

-

154 

Wrist Strap and 

such.

 

1. Always ground when use, otherwise 

 

    these do not function causing damage 

 

    to electronic components, shock to 

 

    operators or an explosion according to 

 

    circumstances.

 

2. Prepare a grounding line for ESD 

 

    separately from the grounding line 

 

    concerning power line. This could 

 

    cause a shock. 

 

 

Warning

    

ground

 

S

 

Size

 

200 mm

 

OAL

 

Reviews: