Operation 

 

Bring the tip of the HC-31 close to the 
area where color distortion was occurred 
on the cathode ray tube. While pushing 
the power switch, gradually pull the HC-31 
away from the screen, and release the 
switch when the distortion stops. 
Repeat the operation or orient the HC-31 
parallel with the tube face.

 

 

 

Plug in the power plug to the wall outlet.

 

● 

For cathode ray tube

 

The same procedure as TV tube.

 

19.05 

If your PC monitor is by aperture-mask system, 
after finishing this procedure, sometimes verti-
cal lines appear on the screen by distortion on 
aperture-musk itself receiving repercussion of 
the demagnetizer, but this is not malfunction. In 
case of this, softly hit the side of the monitor set 
to recover.

 

 

Caution

 

Bring the tip of the HC-31 close to the magnetized object. While pushing the pow-
er switch, gradually pull the HC-31 away from the object approximately 30cm, and 
release the switch. 

● 

For other

 

object

 

1-2-12 Saiwaicho, Naniwa-ku, Osaka 556-0021, Japan

 

Tel : +81-6-6567-3111

   

Fa x : +81-6-6562-0024

 

Summary of Contents for НС-31-220

Page 1: ... 220 Vac 68mT 680Gs 0 45 A 0 43 A 74mT 740Gs 880 g 34 W X59 H X216 D mm 240 Vac 76mT 760Gs 0 41 A DEMAGNETIZER Thank you for purchasing the HOZAN HC 31 220 DEMAGNETIZER With proper care and handling this fine instrument will provide years of trouble free operation Please read this entire instruction manual carefully before attempting to place this instrument in service Please keep this instruction...

Page 2: ...g field Do not point at a person If the operator is using a pacemaker for his her heart this could cause a disorder to the pacemaker When a disorder is felt immediately stop using this demagnetizer and consult a doctor Warning 1 If feel that this device has excessive heat use again after cool the heat enough Using without doing any care could cause dropping of magnetism 2 Be sure to plug off when ...

Page 3: ... from magnetism Measurement apparatus Gauss meter GM 4000 manufactured by Electromagnetic Industries Co Ltd Sensor probe T22078 manufactured by Electromagnetic Industries Co Ltd Distance and magnetic flux density thermal controller The following data shows the relationships between distance and magnetic flux density This has an automatic thermal controller which limits the power and magnetism will...

Page 4: ...TV tube 19 05 If your PC monitor is by aperture mask system after finishing this procedure sometimes verti cal lines appear on the screen by distortion on aperture musk itself receiving repercussion of the demagnetizer but this is not malfunction In case of this softly hit the side of the monitor set to recover Caution Bring the tip of the HC 31 close to the magnetized object While pushing the pow...

Reviews: