1.  Remove the accessories from the pump

outlet.

2.  Holding the pump in one hand, press the

release button (J) on the top of the pump
and open  Strainer Cage. See Fig 5.

3.  Slide the pump out of its location and

wash/rinse the Strainer Cage with clean
water. The hinges on the Strainer Cage
should  also be washed clean at this time.

4.  Reassemble the pump.

Rotor Assembly

1.  Remove the Strainer Cage as described

above.

2.  Release the Pump Chamber, Fig 7 (K), by

rotating it until the two retaining tongues
are clear of the lugs on the Motor Body.

3.  Gently pull the Pump Chamber squarely

away from the Motor Body.

4.  Pull the Rotor Assembly out of the Motor

Body. See Fig 7 (L). 

5.  Wash  out all of the components in clean

water. 

Do not use detergents or other

chemical cleaners.

6.  Replace the Rotor Assembly into the

Motor Body and refit the Pump Chamber
and Strainer Cage.

ALL YEAR PUMP CARE

A quick daily check should be carried out to
ensure that the pump is performing
satisfactorily.

Once a week-

Remove and clean the Strainer

Cage and Fountain Head in accordance with
the general maintenance notes. Depending

on  pond water conditions, cleaning may be
required more frequently.

Once a year-

Completely disassemble the

pump including the Rotor Assembly as
described in the general maintenance notes
and wash all components in clean, fresh
water. Replace worn or broken parts.

SPARE PARTS

Contact the  Consumer Services Helpline on
01844 292002

HOZELOCK CYPRIO 3 YEAR
GUARANTEE

If this pump, excluding the Rotor Assembly,
becomes unserviceable within 3 years of the
date of purchase it will be repaired or
replaced at our option free of charge, unless
in our opinion it has been damaged or
misused. 
Liability is not accepted for damage due to
accident,  improper  installation or use.
Liability is limited to replacement of a faulty
pump. This guarantee is not transferable. It
does not affect your statutory rights. 
To obtain the benefits of the guarantee,
firstly contact Hozelock Cyprio Consumer
Services who may request that the pump is
sent along with proof of purchase directly to
the address below.
DAMAGE CAUSED BY RUNNING THE PUMP
DRY OR BY FROST INVALIDATES THE
GUARANTEE.

FAULT FINDING

WARNING:

ALWAYS UNPLUG OR

DISCONNECT ALL APPLIANCES IN THE
POND FROM THE ELECTRICITY SUPPLY
BEFORE PUTTING YOUR HANDS IN THE
WATER WHILST EQUIPMENT IS BEING
INSTALLED, REPAIRED, MAINTAINED OR
HANDLED.

IMPORTANT - PLEASE KEEP THIS
SECTION FOR REFERENCE

LOW FLOW FROM PUMP

1. Ensure the Strainer Cage is clean.
2. A small diameter outlet pipe will

restrict outlet flow.

3. Clear any blockages and adjust the flow

controls.

NO FLOW FROM PUMP

1. Check power supply is on.
2. Check fuse and wiring.
3. Check the Rotor Assembly is not

jammed, damaged or showing signs of
excessive wear.

4. Ensure the Strainer Cage is clean.

POOR FOUNTAIN DISPLAY.

1. Clean the Fountain Head. (see

maintenance).

Hozelock Cyprio

Haddenham, Aylesbury, Bucks. HP17 8JD.
England.
Tel: +44 (0)1844 292002  Fax: +44 (0)1844 291820
www.hozelock.com

The Aquatics Division of Hozelock Group

33439-000

J

G

I

Fig. 1

F

D

E

Fig. 6

Fig. 4

Fig. 7

L

K

Fig. 5

Fig. 3

Fig. 2

A

B

H

Item Numbers

1. Pump Chamber and Seal.

Z13248 

2. Rotor Assembly.

3419

3. Strainer Cage.

Z13225

4. Fountain Kit.

3426

Reviews: