1. Remove the accessories from the pump
outlet.
2. Holding the pump in one hand, press the
release button (J) on the top of the pump
and open Strainer Cage. See Fig 5.
3. Slide the pump out of its location and
wash/rinse the Strainer Cage with clean
water. The hinges on the Strainer Cage
should also be washed clean at this time.
4. Reassemble the pump.
Rotor Assembly
1. Remove the Strainer Cage as described
above.
2. Release the Pump Chamber, Fig 7 (K), by
rotating it until the two retaining tongues
are clear of the lugs on the Motor Body.
3. Gently pull the Pump Chamber squarely
away from the Motor Body.
4. Pull the Rotor Assembly out of the Motor
Body. See Fig 7 (L).
5. Wash out all of the components in clean
water.
Do not use detergents or other
chemical cleaners.
6. Replace the Rotor Assembly into the
Motor Body and refit the Pump Chamber
and Strainer Cage.
ALL YEAR PUMP CARE
A quick daily check should be carried out to
ensure that the pump is performing
satisfactorily.
Once a week-
Remove and clean the Strainer
Cage and Fountain Head in accordance with
the general maintenance notes. Depending
on pond water conditions, cleaning may be
required more frequently.
Once a year-
Completely disassemble the
pump including the Rotor Assembly as
described in the general maintenance notes
and wash all components in clean, fresh
water. Replace worn or broken parts.
SPARE PARTS
Contact the Consumer Services Helpline on
01844 292002
HOZELOCK CYPRIO 3 YEAR
GUARANTEE
If this pump, excluding the Rotor Assembly,
becomes unserviceable within 3 years of the
date of purchase it will be repaired or
replaced at our option free of charge, unless
in our opinion it has been damaged or
misused.
Liability is not accepted for damage due to
accident, improper installation or use.
Liability is limited to replacement of a faulty
pump. This guarantee is not transferable. It
does not affect your statutory rights.
To obtain the benefits of the guarantee,
firstly contact Hozelock Cyprio Consumer
Services who may request that the pump is
sent along with proof of purchase directly to
the address below.
DAMAGE CAUSED BY RUNNING THE PUMP
DRY OR BY FROST INVALIDATES THE
GUARANTEE.
FAULT FINDING
WARNING:
ALWAYS UNPLUG OR
DISCONNECT ALL APPLIANCES IN THE
POND FROM THE ELECTRICITY SUPPLY
BEFORE PUTTING YOUR HANDS IN THE
WATER WHILST EQUIPMENT IS BEING
INSTALLED, REPAIRED, MAINTAINED OR
HANDLED.
IMPORTANT - PLEASE KEEP THIS
SECTION FOR REFERENCE
LOW FLOW FROM PUMP
1. Ensure the Strainer Cage is clean.
2. A small diameter outlet pipe will
restrict outlet flow.
3. Clear any blockages and adjust the flow
controls.
NO FLOW FROM PUMP
1. Check power supply is on.
2. Check fuse and wiring.
3. Check the Rotor Assembly is not
jammed, damaged or showing signs of
excessive wear.
4. Ensure the Strainer Cage is clean.
POOR FOUNTAIN DISPLAY.
1. Clean the Fountain Head. (see
maintenance).
Hozelock Cyprio
Haddenham, Aylesbury, Bucks. HP17 8JD.
England.
Tel: +44 (0)1844 292002 Fax: +44 (0)1844 291820
www.hozelock.com
The Aquatics Division of Hozelock Group
33439-000
J
G
I
Fig. 1
F
D
E
Fig. 6
Fig. 4
Fig. 7
L
K
Fig. 5
Fig. 3
Fig. 2
A
B
H
Item Numbers
1. Pump Chamber and Seal.
Z13248
2. Rotor Assembly.
3419
3. Strainer Cage.
Z13225
4. Fountain Kit.
3426