background image

INSTALLATION AND OPERATING
INSTRUCTIONS. READ

INSTRUCTIONS CAREFULLY BEFORE
ATTEMPTING INSTALLATION. KEEP
THESE INSTRUCTIONS FOR FUTURE
REFERENCE.

The Hozelock Cyprio EasyClear™
Fountain or Waterfall pump is
designed for submersible use in
outdoor ponds. It is an integrated unit
that provides Mechanical & Biological
Filtration with an Ultra Violet Clarifier,
Fountain or Waterfall.

The appliance is not intended for use
by persons (including children) with
reduced physical, sensory or mental
capabilities, or lack of experience and
knowledge, unless they have been
given supervision or instruction
concerning use of the appliance by a
person responsible for their safety.
Children should be supervised to
ensure that they do not play with the
appliance.

(

Australia & NZ only

) This appliance is

not intended for use by young
children or infirm persons unless they
have been adequately supervised by
a responsible person to ensure that
they can use the appliance safely.
Young children should be supervised
to ensure that they do not play with
the appliance. 

Do not operate or leave the unit in
freezing conditions. 

Do not switch the pump on out of
water! 

The water level should be

above the UVC indicator at the ball
joint (Fig 4A-L).

DO NOT OPERATE THIS UNIT WITHOUT
THE OUTER CAGE ATTACHED. USING
THE UNIT WITHOUT THE OUTER CAGE
MAY INVALIDATE YOUR WARRANTY.

The clear tube inside the unit is made
from quartz glass and care should be
taken during installation and
maintenance. We recommend the use
of eye protection and suitable gloves.

The EasyClear 3000 is fitted with a 5W
UVC lamp. Exposure to Ultra Violet
(UV) radiation can be dangerous and
cause damage to eyes and skin. Under
no circumstances should any attempt
be made to gain access to the lamp
when the unit is switched on. When
switched on, the lamp can be checked
for operation by looking for a bluish
glow from the ball joint outlet (Fig 1-
A). Please note that this may only
become visible in low light conditions.

From 1st January 2005 installing this
product in the garden is classed as
'notifiable' in the revised Building
Regulations for England and Wales.
The Regulations now require you to
tell your local authority building
control department that you intend to
install this product before installation.
Your local authority will let you know
how you can get your installation
approved.

To help ensure your EasyClear’s long
life and to prevent damage, it is fitted
with automatic thermal Overload
Protection. This switches the pump or
UV lamp off if either overheats. If this

General Safety &

Guidelines

Overload Protection

Legislation

UV Caution

Summary of Contents for EASYCLEAR 3000

Page 1: ...2823 3003 EASYCLEAR 3000 Hozelock Ltd Midpoint Park Birmingham B76 1AB England Tel 44 0 121 313 1122 info hozelock com www hozelock com 33854 002 ...

Page 2: ...1 4A 3 5 6 7 4B 8 2 P P O N L M Q R S J K G C E D B A I F H ...

Page 3: ...V X Y V V Z Z W W 10 9 U T 10A ...

Page 4: ...11 5 3 2 4 1 ...

Page 5: ... the ball joint Fig 4A L DO NOT OPERATE THIS UNIT WITHOUT THE OUTER CAGE ATTACHED USING THE UNIT WITHOUT THE OUTER CAGE MAY INVALIDATE YOUR WARRANTY The clear tube inside the unit is made from quartz glass and care should be taken during installation and maintenance We recommend the use of eye protection and suitable gloves The EasyClear 3000 is fitted with a 5W UVC lamp Exposure to Ultra Violet U...

Page 6: ...UPPLY BEFORE PUTTING YOUR HANDS IN THE WATER WHILST EQUIPMENT IS BEING INSTALLED REPAIRED MAINTAINED OR HANDLED Do not use the supply cable to lift the unit as this may cause damage We recommend fitting a lifting cord to the hook feature on the base when the filter is installed in deep water Fig 1 H Check that the voltage marked on the unit corresponds to the mains supply A 10mA OR 30mA RESIDUAL C...

Page 7: ...en using the EasyClear for a waterfall the entire unit should be submersed Connection Place the unit next to the pond and route the cable back to the mains supply Ensure that you allow for enough cable for positioning the product in the desired location in the pond Bell Fountain Fig 1 Locate the Bell Support B to the Bell Main Body C and push fully home Position the Bell D to the Body Assembly and...

Page 8: ...casionally it will become necessary to clean or replace parts Refer to the safety sections before attempting any maintenance Fountain Head Fig 1 I Follow the below procedure if the fountain head is blocked 1 Place a coin or similar in the slot and gently lever off the fountain head 2 Rinse in clean water and reassemble Foam Follow the below procedure if flow appears reduced 1 Release the Foam Cove...

Page 9: ...f the two o rings on the Quartz Tube Assembly Fig 11 3 If these are damaged in any way or you can not guarantee a water tight seal contact Hozelock Consumer Services Biological Filter Normally there is no need to remove the biomedia as any cleaning may kill the colonies of bacteria that make toxic waste harmless 1 Remove the foam 2 The bag of Kaldnes Biomedia Fig 7 P can be removed for cleaning 3 ...

Page 10: ...uns for 12 months after purchase provided that You have followed the installation and operating instructions You are using equipment of the correct size and stocking level for your pond You consult our Helpline 44 0 121 313 1122 early enough for any problems to be put right The product has been returned undamaged A refund can only be authorised by Hozelock Cyprio and is made at the place of purcha...

Page 11: ... white flap inside pump chamber moves freely e Ensure rotor is clean and moves freely POOR FOUNTAIN DISPLAY a As above b Clean the Fountain Head UV LAMP NOT WORKING a Check power supply is on b Check fuse RCD and wiring c Replace the lamp d The Overload Protection may have operated see Overload Protection section PUMP NOT WORKING a Check power supply is on b Check fuse RCD and wiring c Check the r...