LEAKAGE TEST
Gas connections on the heater are leak
tested at the factory prior to shipment.
A complete gas tightness check must
be performed at the installation site due
to possible mishandling in shipment or
excessive pressure being applied to the
heater.
Make a soap solution of one part liquid
detergent and one part water. The soap
solution can be applied with a spray bottle,
brush or rag. Soap bubbles will appear in
case of a leak.
The heater must be checked with a full
cylinder.
Make sure the safety control valve is in the
OFF position.
Turn the gas supply ON.
In case of a leak, turn off the gas supply.
Tighten any leaking � ttings, then turn the
gas supply on and recheck.
Never leak test while smoking.
OPERATION AND STORAGE
TO TURN ON THE HEATER
1. Turn on the valve on the gas supply
cylinder completely.
2. Press and turn the variable control knob
to PILOT position (counter-clockwise
90º).
3. Press down the variable control knob
and hold for 30 seconds. While holding
down the variable control knob, press
the igniter button several times until
the pilot � ame lights. Release the
variable control knob after the pilot
� ame lights.
Note:
- If a new tank has just been connected,
please allow at least one minute for
the air in the gas pipeline to purge out
through the pilot hole.
- When lighting the pilot � ame make
sure that the variable control knob
is continuously pressed down while
pressing the igniter button. Variable
control knob can be released after the
pilot � ame lights.
- Pilot � ame can be watched and checked
from the small round window with
sliding lid located at the bottom of the
� ame screen (to the left or right side of
the controller).
- If the pilot � ame does not light or it
goes out, repeat step 3.
4. After the pilot � ame lights, turn the
variable control knob to maximum
position and leave it there for 5 minutes
or more before turning the knob to
desired temperature position.
TO TURN OFF THE HEATER
1. Turn the variable control knob to PILOT
position.
2. Press and turn the variable control knob
to OFF position.
Summary of Contents for 09HW-A
Page 12: ...12 DK FEJLAFHJÆLPNING ...
Page 24: ...24 NO FEILSØKING ...
Page 36: ...36 SE CHECKLISTA VID PROBLEM ...
Page 48: ...48 FI ONGELMIEN TARKISTUSLISTA ...
Page 60: ...60 GB PROBLEMS CHECK LIST ...
Page 72: ...72 DE Fehlerbehebung ...
Page 74: ...74 ET ...
Page 75: ...75 NO SE FI GB DE DK ET ...
Page 76: ...76 ET ...
Page 77: ...77 NO SE FI GB DE DK ET ...
Page 78: ...78 ET ...
Page 79: ...79 NO SE FI GB DE DK ET ...
Page 80: ...80 ET ...
Page 81: ...81 NO SE FI GB DE DK ET ...
Page 82: ...82 ET ...
Page 83: ...83 NO SE FI GB DE DK ET ...
Page 84: ...84 ET ...