Failure of another drive during rebuild
If a non-correctable read error occurs on another physical drive in the array during the rebuild process,
the Online LED of the replacement drive stops blinking and the rebuild abnormally terminates.
If this situation occurs, restart the server and the storage system. The system may temporarily become
operational long enough to allow recovery of unsaved data. In any case, locate the faulty drive, replace
it, and restore data from backup.