Message
Type
Description
Action
81 SMART DRIVE
ALERT BOX #<n>,
BAY <n>
Informational
A SCSI hard drive may be
close to failing. This was
determined either by the
hard drive
fi
rmware itself
using SMART technology or
by the array controller using
monitor and performance
testing.
The hard drive should
be replaced as soon as
possible.
82 DRIVE HOT ADDED
BOX #<n>, BAY <n>
Informational
A SCSI hard drive has
been added to the MSA
chassis or attached external
storage enclosure.
83 DRIVE HOT
REMOVED BOX #<n>,
BAY <n>
Informational
A SCSI hard drive has been
removed from the MSA
chassis or attached external
storage enclosure.
84 DRIVE FAILURE
BOX #<n>, BAY <n>
Error
A SCSI hard drive in the
MSA chassis or attached
external storage enclosure
has failed. If the hard drive
was part of a con
fi
gured
volume, then the state of the
volume will depend on the
fault tolerance used.
The hard drive should
be replaced as soon as
possible.
85 BAD DRIVE
FRMWARE BOX #<n>,
BAY <n>
Error
A SCSI hard drive has
been detected that has
known, bad
fi
rmware on it.
Continued use of this hard
drive could result in hard
drive failure, decreased
performance, or data loss.
Either the hard drive
fi
rmware
should be updated or
the hard drive should
be replaced as soon as
possible.
86 DRIVE POSITION
CHANGE DETECTED
Informational
The SCSI hard drives that
make up a con
fi
gured
volume have been
physically moved within
the MSA1000 chassis or
attached external storage
enclosure. The array
controller has updated its
con
fi
guration information
accordingly.
87 DRIVE POSITION
CHANGE INVALID
Informational
The SCSI hard drives that
make up a con
fi
gured
volume have been
physically moved in such a
way that the array controller
can no longer access the
con
fi
gured volume.
The MSA should be powered
off and the hard drives
restored to their original
positions.
88 NON-COMPAQ DRIVE
BOX #<n>, BAY <n>
Informational
An unsupported hard
drive was located in the
indicated bay of the storage
enclosure.
46
LCD panel and message descriptions
Summary of Contents for 201723-B21 - HP StorageWorks Modular SAN Array 1000 Hard Drive
Page 8: ...8 ...
Page 12: ...12 About this guide ...
Page 18: ...18 Specifications ...
Page 28: ...28 System components and LEDs ...
Page 58: ...58 LCD panel and message descriptions ...
Page 94: ...94 Customer replaceable components ...
Page 98: ...98 Capacity expansion and extension ...
Page 104: ...104 Hard drive failures and faulted LUNs ...
Page 110: ...110 SCSI hard drive firmware ...