Message
Type
Description
Action
106 VOLUME #<n>
STATE WAITING TO
REBUILD
Informational
The con
fi
gured volume is
waiting to start rebuilding
data on a SCSI hard drive
that replaces a previously
failed drive. The rebuild
may not have started yet
because the array controller
is already performing
a rebuild on another
con
fi
gured volume.
107 VOLUME #<n>
STATE WAITING TO
EXPAND
Informational
The con
fi
gured volume is
waiting to start a volume
expansion operation.
The expansion may have
not started yet because
another con
fi
gured volume
is undergoing expansion or
a rebuild is occurring on
the con
fi
gured volume.
108 VOLUME #<n>
STATE MISSING
DRIVES
Error
The con
fi
gured volume is
missing too many of the
SCSI hard drives that it is
composed of, making it
unusable. The volume is
disabled.
Power off the MSA and
then all attached storage
enclosures. Unplug and
reinsert all SCSI hard drives
ensuring they are fully seated
in their bays. Check the
cables connecting the MSA
to any attached storage
enclosures. Power on the
attached enclosures and
then the MSA.
109 VOLUME #<n>
STATE WRONG DRIVE
REPLACED
Error
The con
fi
gured volume
appears to have had
known, good SCSI hard
drives replaced instead of
known, failed hard drives.
The MSA should be powered
off and the good hard drives
should be restored while the
failed hard drives should be
replaced.
110 VOLUME #<n>
EXPANSION DISABLED
Informational
The volume expansion
operation on the con
fi
gured
volume has been disabled.
This may be because
a rebuild operation
is ongoing, another
expansion is already
running, or the cache
memory is disabled due
to a low battery. The
expansion will start once
the condition has been
cleared.
111 VOLUME #<n>
INITIALIZING PARITY
Informational
The array controller is
calculating and storing
parity information for the
con
fi
gured volume and
therefore performance may
be lower until it completes.
48
LCD panel and message descriptions
Summary of Contents for 201723-B21 - HP StorageWorks Modular SAN Array 1000 Hard Drive
Page 8: ...8 ...
Page 12: ...12 About this guide ...
Page 18: ...18 Specifications ...
Page 28: ...28 System components and LEDs ...
Page 58: ...58 LCD panel and message descriptions ...
Page 94: ...94 Customer replaceable components ...
Page 98: ...98 Capacity expansion and extension ...
Page 104: ...104 Hard drive failures and faulted LUNs ...
Page 110: ...110 SCSI hard drive firmware ...