Message
Type
Description
Action
306 FIRMWARE FLASH
STARTED
Informational
The array controller in
the MSA has started the
fi
rmware
fl
ash process.
Do not turn off power
to the system until it has
completed. This could take
several minutes.
307 FIRMWARE FLASH
DONE
Informational
The array controller in the
MSA has completed the
fi
rmware
fl
ash process. It is
now safe to restart the MSA
and begin using the new
fi
rmware. In dual-controller
con
fi
gurations, the new
fi
rmware is cloned onto the
other controller during the
startup routine.
308 FIRMWARE FLASH
FAILED
Error
The array controller in
the MSA has failed the
fi
rmware
fl
ash process.
Attempt the
fl
ash process
again.
Should the issue persist,
contact HP support.
309 EMU FLASH
STARTED
Informational
The EMU has started the
fi
rmware
fl
ash process.
Do not turn off the power
to the system until it has
completed. This could take
fi
ve minutes.
310 EMU FLASH DONE
Informational
The EMU has completed the
fi
rmware
fl
ash process. It is
now safe to turn off power
to the system.
311 EMU FLASH
FAILED
Error
The EMU has failed the
fi
rmware
fl
ash process.
Attempt the
fl
ash process
again.
Should the issue persist,
contact HP support.
312 FIRMWARE FLASH
STARTED ON BOX #<n>
Informational
A
fi
rmware
fl
ash operation
has started on an attached
storage enclosure.
313 FIRMWARE FLASH
DONE ON BOX #<n>
Informational
A
fi
rmware
fl
ash operation
has completed on an
attached storage enclosure.
Restart the storage enclosure
to enable the new
fi
rmware.
314 FIRMWARE FLASH
FAILED ON BOX #<n>
Error
A
fi
rmware
fl
ash operation
has failed on an attached
storage enclosure.
Attempt the
fl
ash process
again.
Should the issue persist,
contact HP support.
400 STORAGE BOX
#<n> FAN OK
Informational
A fan in the speci
fi
ed
storage enclosure that
was previously marked as
failed or degraded is now
operating normally.
401 STORAGE BOX
#<n> FAN FAILED
Error
A fan in the speci
fi
ed
storage enclosure has
failed. The MSA may
now be susceptible to
overheating if corrective
action is not taken.
Check all fans and ensure
they are operating. Any
failed fans should be
replaced.
maintenance and service guide
53
Summary of Contents for 201723-B21 - HP StorageWorks Modular SAN Array 1000 Hard Drive
Page 8: ...8 ...
Page 12: ...12 About this guide ...
Page 18: ...18 Specifications ...
Page 28: ...28 System components and LEDs ...
Page 58: ...58 LCD panel and message descriptions ...
Page 94: ...94 Customer replaceable components ...
Page 98: ...98 Capacity expansion and extension ...
Page 104: ...104 Hard drive failures and faulted LUNs ...
Page 110: ...110 SCSI hard drive firmware ...