Message
Type
Description
Action
402 STORAGE BOX
#<n> FAN DEGRADED
Error
A fan in the speci
fi
ed
storage enclosure is not
operating at full ef
fi
ciency.
The fan may eventually fail.
Check all fans and ensure
they are operating. Any
failed fans should be
replaced.
403 STORAGE BOX
#<n> FAN HOT
INSERTED
Informational
An fan in the speci
fi
ed
storage enclosure has been
hot-added.
404 STORAGE BOX
#<n> FAN HOT
REMOVED
Informational
A fan in the speci
fi
ed
storage enclosure has been
removed.
405 STORAGE BOX
#<n> TEMPERATURE OK
Informational
The temperature in the
speci
fi
ed storage enclosure
is now back in the normal
operating range.
406 STORAGE BOX
#<n> OVERHEATING
Error
The temperature in the
speci
fi
ed storage enclosure
is starting to exceed the
normal operating range.
Check all fans and ensure
they are operating. Any
failed fans should be
replaced. Ensure that there
is a module or blanking
panel (cover plate) in all
MSA chassis bays and slots.
Empty bays affect the air
fl
ow
and cooling ability of the
MSA.
407 STORAGE BOX
#<n> OVERHEATED
Error
The temperature in the
speci
fi
ed storage enclosure
has exceeded the safe
operating range.
The MSA should be powered
off as soon as possible
and immediately after
that, the enclosure should
be powered off, to avoid
hardware failure.
Check all MSA fans and
ensure they are operating.
Any failed fan should be
replaced. Ensure that there
is a module or blanking
panel (cover plate) in all
MSA chassis bays and slots.
Empty bays affect the air
fl
ow
and cooling ability of the
MSA.
408 STORAGE BOX
#<n> POWER SUPPLY
OK
Informational
The power supply in the
speci
fi
ed storage enclosure
that was previously marked
as failed or degraded is
now operating normally.
409 STORAGE BOX
#<n> POWER SUPPLY
FAILED
Error
A power supply in the
speci
fi
ed storage enclosure
has failed.
Check all power supplies and
ensure they are operating.
Any failed power supplies
should be replaced.
410 STORAGE BOX
#<n> POWER SUPPLY
ADDED
Informational
A power supply in the
speci
fi
ed storage enclosure
has been added.
411 STORAGE BOX
#<n> POWER SUPPLY
REMOVED
Informational
A power supply in the
speci
fi
ed storage enclosure
has been removed.
54
LCD panel and message descriptions
Summary of Contents for 201723-B21 - HP StorageWorks Modular SAN Array 1000 Hard Drive
Page 8: ...8 ...
Page 12: ...12 About this guide ...
Page 18: ...18 Specifications ...
Page 28: ...28 System components and LEDs ...
Page 58: ...58 LCD panel and message descriptions ...
Page 94: ...94 Customer replaceable components ...
Page 98: ...98 Capacity expansion and extension ...
Page 104: ...104 Hard drive failures and faulted LUNs ...
Page 110: ...110 SCSI hard drive firmware ...