2
1
15593
3.
Close the ejector lever against the front of the hard drive (
2
).
4.
Verify that the hard drive is
fi
rmly engaged and that the ejector lever is latched.
CAUTION:
Data can be lost if the hard drive is not
fi
rmly seated.
5.
As the hard drive begins to spin, the drive LEDs will illuminate, indicating that the system has
recognized the new drive. In fault-tolerant con
fi
gurations, allow the replacement hard drive to
be reconstructed automatically from parity data stored on the other hard drives. While the data
is being rebuilt, the LEDs will
fl
ash.
Verifying proper operation
The hard drive LEDs light one at a time and then turn off together to indicate that the system has
recognized the new drive. In fault tolerant con
fi
gurations, allow the replacement hard drive to be
reconstructed automatically with data from the other hard drives. While reconstruction is in progress,
the online LEDs
fl
ash.
maintenance and service guide