HP StorageWorks 1000 Modular Smart Array installation guide
29
Table 1: MSA1000 specifications
Parameter
English
Metric
Dimensions
Height
Depth
Width
6.9 in. (4U)
20.5 in.
19.0 in.
17.5 cm (4U)
52.1 cm
48.3 cm
Weight
Shipping configuration
68.8 lb
31.21 kg
Input power requirements
Rated input voltage
Rated input frequency
Rated input current
Input power (max.)
100 to 240 VAC
50 to 60 Hz
7.35 A Max
641 W*
100 to 240 VAC
50 to 60 Hz
7.35 A Max
641 W*
Heat dissipation (max.)
2187 Btu/hr*
2187 Btu/hr*
Temperature range
Operating
Shipping
50
°
to 95
°
F
-22
°
to 122
°
F
10
°
to 35
°
C
-30
°
to 50
°
C
Relative humidity (non-condensing)
Operating
Non-operating
10% to 90%
up to 95%
10% to 90%
up to 95%
Maximum wet bulb temperature
Long-term storage
Short-term storage
84.2
°
F
86
°
F
29
°
C
30
°
C
*Input power and heat dissipation specifications are maximum values and apply to
worst-case conditions at full rated power supply load. The power/heat dissipation for your
installation will vary depending on the equipment configuration.
Summary of Contents for 201723-B21 - HP StorageWorks Modular SAN Array 1000 Hard Drive
Page 58: ...Installation procedures All deployments 58 ...
Page 64: ...Configuration procedures Windows environments 64 ...
Page 70: ...Configuration procedures Linux environments 70 ...
Page 76: ...Configuration procedures HP UX environments 76 ...
Page 82: ...Configuration procedures OpenVMS environments 82 ...
Page 94: ...Configuration procedures Other environments 94 ...
Page 98: ...Powering off and powering on the MSA 98 ...
Page 104: ...Electrostatic discharge 104 ...