Configuration procedures—Windows environments
62
d.
In multipathing environments, install the following components
(required in all dual-controller
configurations)
:
• MPIO Full Featured DSM
• Multipath Manager
IMPORTANT:
When installing the MPIO components, if prompted, remove the Support
Software CD from the CD-ROM drive and restart the server.
5.
After all desired components are installed, remove the Support Software CD from the CD-ROM
drive.
6.
Restart the server.
7.
Repeat these installation procedures on each Windows server that will access the MSA.
NOTE:
To initially start the ACU and enter basic settings, do the following:
•
From the desktop, click
Start>Programs>HP System Tools>hp Array Configuration Utility>Set up
hp Array Configuration Utility
.
•
Click
Next
to set the execution mode (be sure to select Local Application), and then enter
passwords, the device trust mode, and remote access settings.
For complete information about using the ACU to configure the storage, see ACU online help or the
Configuration Arrays reference guide.
Updating MSA controller firmware (if necessary)
If you need to update the firmware on your MSA controller to a version downloaded from the MSA
website, do so at this time.
For information on determining whether you need to update MSA controller firmware, see the
following sections in this guide:
•
”
Determine which version of MSA controller firmware to use
” on page 15
•
”
Obtain desired controller firmware and Support Software CD versions
” on page 54
For instructions on updating MSA controller firmware, see the MSA1000/1500 firmware updating
guide, available on the Technical documentation page of the MSA1000 website:
http://www.hp.com/go/msa1000
.
IMPORTANT:
After updating MSA controller firmware, be sure to check the status of the MSA for
unexpected issues. Verify the status of the connections, defined profile types, redundancy settings,
and storage configuration.
Summary of Contents for 201723-B21 - HP StorageWorks Modular SAN Array 1000 Hard Drive
Page 58: ...Installation procedures All deployments 58 ...
Page 64: ...Configuration procedures Windows environments 64 ...
Page 70: ...Configuration procedures Linux environments 70 ...
Page 76: ...Configuration procedures HP UX environments 76 ...
Page 82: ...Configuration procedures OpenVMS environments 82 ...
Page 94: ...Configuration procedures Other environments 94 ...
Page 98: ...Powering off and powering on the MSA 98 ...
Page 104: ...Electrostatic discharge 104 ...