Configuration procedures—Other environments
90
Operating system-specific notes
NOTE:
SCO UNIX, VMware, OpenVMS, and Tru64 UNIX do not use the provided MSA Support
Software CD. These operating systems use the MSA-CLI to configure the storage and obtain the HBA
drivers and multipathing tools from a different source, such as through operating system updates or
the HP website.
NetWare environments
•
Single-controller configurations are supported for use with active/passive firmware only.
•
Dual-controller configurations are supported for use with either active/passive (using Secure Path
as the multipathing software) or active/active firmware (using the native NetWare MPIO
multipathing software).
•
For information on upgrading the MSA to active/active, see the migration instructions for
NetWare environments, available on the Technical documentation page of the MSA1000
website:
http://www.hp.com/go/msa1000
.
•
If desired, NetWare environments can use the Array Configuration Utility to configure the MSA.
The ACU is provided on the MSA Support Software CD and can be installed and run from a
Windows or Linux server, or, the NetWare server can boot to the CD and run the ACU offline
from the CD.
•
If using the ACU to configure the MSA, install Netscape Navigator version 6.2 or later or
Mozilla, version 1.0.2 or later with Personal Security Manager.
•
After installing the MSA, be sure to set the host mode for each NetWare connection to
netware
.
•
If the MSA is upgraded to 7.0 or later active/active firmware, do the following to activate the
native MPIO provided by Novell.
From the console:
a.
Enter
edit
c:\nwserver\startup.ncf
.
b.
Add the following entry as the first line in the
startup.ncf
file:
set multi-path support = on
c.
Locate the following entry and modify it:
d.
For each HBA, verify that the following options are specified:
load ql2x00.ham
slot=x/luns/allpaths/portnames
, where x represents the slot number.
NOTE:
The Native MPIO solution can co-exist with HP Secure Path for NetWare.
Old entry
Modified entry
LOAD SCSIHD.CDM
LOAD SCSIHD.CDM /AEN
Summary of Contents for 201723-B21 - HP StorageWorks Modular SAN Array 1000 Hard Drive
Page 58: ...Installation procedures All deployments 58 ...
Page 64: ...Configuration procedures Windows environments 64 ...
Page 70: ...Configuration procedures Linux environments 70 ...
Page 76: ...Configuration procedures HP UX environments 76 ...
Page 82: ...Configuration procedures OpenVMS environments 82 ...
Page 94: ...Configuration procedures Other environments 94 ...
Page 98: ...Powering off and powering on the MSA 98 ...
Page 104: ...Electrostatic discharge 104 ...