background image

Optional SNMP/Serial

Optional SNMP/Serial

Optional SNMP/Serial

Optional SNMP/Serial
Port Card

Port Card

Port Card

Port Card

Ideal for networked environments, this option card enables network administrators to remotely diagnose,
monitor and reboot network devices via SNMP.

Optional Six Port Card

Optional Six Port Card

Optional Six Port Card

Optional Six Port Card

This option card lets you communicate (via standard DB-9 serial ports) with multiple servers. The
maximum number of servers that can be connected using this card depends on the number of load
segments available on the UPS. The R5500 XR has 2 load segments, so this card will allow you to serially
communicate with up to 3 servers. And the R5500 XR has 2 load segments, so you can communicate
with up to 2 servers using this card.

Extended Runtime Module

Extended Runtime Module

Extended Runtime Module

Extended Runtime Module
(ERM), R5500 XR

(ERM), R5500 XR

(ERM), R5500 XR

(ERM), R5500 XR

The UPS R5500 XR supports up to two Extended Runtime Modules. Each module is 3U (5.25 inches), a
rack mountable battery module that extends your overall battery runtime.

QuickSpecs

HP UPS R5500 XR Uninterruptible Power System

HP UPS R5500 XR Uninterruptible Power System

HP UPS R5500 XR Uninterruptible Power System

HP UPS R5500 XR Uninterruptible Power System

Innovative Options to Meet Your Data Center Needs

DA - 11871   Worldwide — Version 7 — February 24, 2006

Page 6

Summary of Contents for 326529-B31

Page 1: ...eXtended Runtime capable UPS models 1 REPO port 7 Load segment 2 two IEC 320 C19 receptacles and two IEC 320 C13 receptacles 2 Ground bonding screw 8 Battery circuit breaker 3 Communications port option slot 9 Cord retention clip attach locations 4 Load segment 1 circuit breaker 10 ERM connector 5 Load segment 1 two IEC 320 C19 receptacles and two IEC 320 C13 receptacles 11 PDU output NEMA L6 30 r...

Page 2: ...mate long term battery reliability with HP Enhanced Battery Management Enhanced system flexibility with two independently controlled load segments Support for Remote Emergency Power Off REPO circuitry Easy serviceability through modular design Hot Swappable Battery and Electronics Modules Backed by a three year warranty with the first year including parts and labor HP s Pre Failure warranty and a ...

Page 3: ...ost of ownership and receive the best in the industry protection for your critical equipment Enhanced System Enhanced System Enhanced System Enhanced System Flexibility with HP Option Flexibility with HP Option Flexibility with HP Option Flexibility with HP Option Cards Cards Cards Cards The UPS R5500 XR models are equipped with a standard serial communications port via an internal slot This optio...

Page 4: ...ies Hot Swappable Batteries Hot Swappable Batteries Hot Swappable Batteries and Electronics Modules and Electronics Modules and Electronics Modules and Electronics Modules The UPS R5500 XR is modular in design and both the battery and the electronics modules are hot swappable HP UPSs are designed with simple access through the front panel Users can safely install new batteries and even the electro...

Page 5: ...y of our worldwide sales offices or resellers or visit our worldwide web site on the internet at http www hp com hps carepack NOTE NOTE NOTE NOTE For more complete information on HP Services offerings customers and resellers please visit us at http www hp com hps NOTE NOTE NOTE NOTE Additional information regarding worldwide limited warranty and technical support is available at http h18004 www1 h...

Page 6: ...has 2 load segments so this card will allow you to serially communicate with up to 3 servers And the R5500 XR has 2 load segments so you can communicate with up to 2 servers using this card Extended Runtime Module Extended Runtime Module Extended Runtime Module Extended Runtime Module ERM R5500 XR ERM R5500 XR ERM R5500 XR ERM R5500 XR The UPS R5500 XR supports up to two Extended Runtime Modules E...

Page 7: ...192185 B21 Extended Runtime Module ERM R5500 XR Extended Runtime Module ERM R5500 XR Extended Runtime Module ERM R5500 XR Extended Runtime Module ERM R5500 XR 326564 B21 QuickSpecs HP UPS R5500 XR Uninterruptible Power System HP UPS R5500 XR Uninterruptible Power System HP UPS R5500 XR Uninterruptible Power System HP UPS R5500 XR Uninterruptible Power System Related Options DA 11871 Worldwide Vers...

Page 8: ...ceptacle LS1 1 x IEC 309 32Amp for Int l model Factory default setting Kit Contents Kit Contents Kit Contents Kit Contents HP UPS R5500 XR HP Power Management Software CD Power Products Documentation CD Depth adjustable fixed rack mounting rails mounting brackets cord retention clips Communications cable 4 PDU sticks 8 x C13 outlets each Two 10 Amp IEC to IEC jumper cords Unit Dimensions Unit Dime...

Page 9: ...nt l model 6000 VA 5400 Watt 6000 VA 5400 Watt 6000 VA 5400 Watt 6000 VA 5400 Watt Load Percent Load Percent Load Percent Load Percent With Standby Battery With Standby Battery With Standby Battery With Standby Battery Minutes With One Extended Runtime With One Extended Runtime With One Extended Runtime With One Extended Runtime Module Module Module Module Minutes With Two Extended Runtime With Tw...

Page 10: ...ators LED Indicators LED Indicators LED Indicators LED and switch membrane integrated into the front panel with four button control three buttons for UPS power control and one button under the front bezel for configuration Environmental and Safety Environmental and Safety Environmental and Safety Environmental and Safety Operating Temperature Operating Temperature Operating Temperature Operating T...

Page 11: ...cts and services Nothing herein should be construed as constituting an additional warranty HP shall not be liable for technical or editorial errors or omissions contained herein QuickSpecs HP UPS R5500 XR Uninterruptible Power System HP UPS R5500 XR Uninterruptible Power System HP UPS R5500 XR Uninterruptible Power System HP UPS R5500 XR Uninterruptible Power System Technical Specifications DA 118...