2 Installing the HP 517
The HP 517 is designed to be mounted on a standard NEMA-WD6 (US) or BS 4662 (International)
electrical outlet box.
If you use the optional HP Unified Wired-WLAN Walljack Table/Flush Wall Mount Kit (JL022A),
the HP 517 can be mounted on a desktop or wall.
The end user is responsible for ensuring that installation and use comply with local safety and radio
regulations.
IMPORTANT:
This device requires professional installation. Consult a professional installer trained
in RF installation and knowledgeable in local regulations including:
•
Building and wiring codes
•
Safety regulations
•
Channel, power, and indoor/outdoor restrictions
•
License requirements for the intended country
Planning the installation site
Determine an appropriate location to mount the unit. Use the following guidelines to select the
installation site.
CAUTION:
To ensure adequate ventilation when installed on an electrical box or wall, the
ventilation slots must not be blocked in any way. Ensure that there is at least 15.25 cm (6 inches)
of clearance from all vents.
Be sure to install the unit in an area that is well ventilated and maintains an ambient temperature
of less than 40°C (104°F). If the installation area has any obstructions to air flow, you must take
steps to ensure adequate airflow is maintained. Do not install in enclosed spaces, at ground level,
or close to or directly above any heat sources or heat-emitting devices, such as:
•
Radiators
•
Portable room heaters
•
The back of refrigerators or compressors
•
Direct sunlight
•
Transformers
•
Power pack units of halogen or similar lighting fixtures or appliances
CAUTION:
To avoid signal interference, do not install the HP 517 near or behind known RF
absorbers, reflectors, and interference sources. Examples of sources that degrade RF performance
include:
•
Cement and brick
•
Objects that contain water
•
Metal
•
Microwave ovens
•
Wireless phones and headsets
•
Mirrors
6
Installing the HP 517