7-7
Adjustments/Calibrations
DROP DETECT CALIBRATION
In this procedure, the position of the drop detect sensor relative to the four print cartridges is
calibrated. Four values are calculated and stored in the plotter EEROM.
Perform the drop detect calibration whenever the:
Drop Detect Calibration is accessible through the ª
Service Tests
º menu. To perform the drop
detect calibration, do the following:
1. Press
Enter
at the ª
Status
º display.
2. Use the arrow buttons to scroll to the ª
Utilities
º main menu. Press
Enter
.
3. Simultaneously press the
Enter
and the
Up Arrow
buttons to access the
ªService
Test
º submenu.
4. Scroll to the ª
Drop Detect Calib
º submenu. Press
Enter
.
5. Messages in the plotter display will inform you that the calibration is in process and
to press the
Enter
button after a successful calibration.