![background image](http://html.mh-extra.com/html/hp/70427a/70427a_user-manual_157664268.webp)
HP 70427A/HP 70428A User’s Guide
10-25
Softkeys and Displays
ALC ON| OFF
ALC ON| OFF
This softkey enables or disables the triggering of an automatic leveling
process for the source and for the downconverter and tunable source LO.
When
ON
is underlined, the leveling process is triggered each time a new
output power (source) or LO power (downconverter and tunable source) is
entered.
The leveling process lasts for a few seconds. During this time the level is
measured repeatedly with the internal voltmeter and then the level is
adjusted.
Path
Service Misc Power Control ALC ON | OFF
HP-IB Command
SOUR:ALC 0
selects
OFF
SOUR:ALC 1
selects
ON
Figure 10-24